Suppr超能文献

用化学电离质谱法分析1,3-双(2-氯乙基)-1-亚硝基脲

Analysis for 1,3-bis(2-chloroethyl)-1-nitrosourea by chemical ionization mass spectrometry.

作者信息

Weinkam R J, Wen J H, Furst D E, Levin V A

出版信息

Clin Chem. 1978 Jan;24(1):45-9.

PMID:618665
Abstract

We used chemical ionization mass spectrometry to quantify the cancer chemotherapeutic agent 1,3-bis(2-chloroethyl)-1-nitrosourea in biological fluids. A stable isotope-labeled internal standard was added to the fluid being analyzed. Protonated molecular ion intensity ratios were determined by selected ion monitoring of sample extracts inserted directly into the chemical ionization source. Peak ratios were calculated for chlorine isotope ratios in their natural abundance, to verify the integrity of the data acquired, and to compute the drug concentration. The assay was applied to measure the compound in rat blood and plasma and in human plasma, and to monitor in vitro metabolism in rat-liver microsomal preparations. For the analyses we used a quadrupole mass spectrometer interfaced to a commercial computer system. Data-system characteristics are described.

摘要

我们使用化学电离质谱法对生物流体中的癌症化疗药物1,3 - 双(2 - 氯乙基)-1 - 亚硝基脲进行定量。向被分析的流体中加入稳定同位素标记的内标。通过对直接插入化学电离源的样品提取物进行选择离子监测来测定质子化分子离子强度比。计算天然丰度下氯同位素比的峰比,以验证所采集数据的完整性,并计算药物浓度。该测定法用于测量大鼠血液、血浆以及人血浆中的该化合物,并监测大鼠肝微粒体制剂中的体外代谢。分析过程中我们使用了与商用计算机系统相连的四极质谱仪。文中描述了数据系统的特性。