Suppr超能文献

含锌和铜的宫内节育器对血清中锌和铜水平的影响。

The effect of intrauterine devices containing zinc and copper on their levels in serum.

作者信息

Anteby S O, Bassat H A, Yarkoni S, Aboulafia Y, Sadovsky E

出版信息

Fertil Steril. 1978 Jan;29(1):30-4. doi: 10.1016/s0015-0282(16)43032-3.

Abstract

Serum levels of copper and zinc were determined in 11 health women in whom Latex Leaf intrauterine devices (IUDs) containing copper and zinc had been inserted. Patients with low levels of serum copper or zinc before insertion usually had increased levels of either of these metals while using the device, but they did not exceed the upper limits of normal values. When the group was considered as a whole, the serum levels of zinc showed a slight tendency to increase with duration of IUD use, whereas there was no statistical difference between the serum levels of copper before and after insertion of the IUD.

摘要

对11名已植入含铜和锌的乳胶叶宫内节育器(IUD)的健康女性测定了血清铜和锌水平。植入前血清铜或锌水平较低的患者在使用该装置时,这两种金属中的任何一种水平通常都会升高,但未超过正常值上限。将该组作为一个整体考虑时,血清锌水平显示出随IUD使用时间延长而略有升高的趋势,而IUD植入前后血清铜水平无统计学差异。