Hérion P, Portetelle D, Franssen J D, Urbain J, Bollen A
Biosci Rep. 1983 Apr;3(4):381-8. doi: 10.1007/BF01122903.
Using two monoclonal antibodies directed against urokinase, we have developed a micro enzyme-linked immunosorbant assay (ELISA) to detect and measure urokinase in biological fluids. The system presents the following characteristics: simple and rapid procedure, reproducibility, sensitivity (urokinase levels down to 1 ng/ml) and evaluation of the enzyme in biological fluids such as urine, pleural effusions, and ascitic fluids without preliminary purification.