Sixteen cases with uterine perforation by a copper intrauterine device (IUD) are presented. In 13 cases the IUD had been inserted within 5 months following delivery, and in 6 cases the insertion had been painful. Missing string was the first sign in most cases. Laparatomy was performed in all cases to remove the IUD. The IUD was adherent to omentum or sigmoid in 10 cases. There is an increased risk of uterine perforation if the IUD is inserted postpartum during lactation and involution of the uterus. Therefore a painful IUD insertion and a missing string demand investigation of a partial or complete perforation.

摘要

本文报告了16例宫内节育器(IUD)致子宫穿孔的病例。13例在产后5个月内放置IUD,6例放置时伴有疼痛。多数病例中,尾丝消失是首要征象。所有病例均行剖腹手术取出IUD。10例IUD与大网膜或乙状结肠粘连。如果在产后哺乳期子宫复旧过程中放置IUD,子宫穿孔风险会增加。因此,放置IUD时疼痛及尾丝消失需要排查部分或完全穿孔情况。

相似文献

1
Uterine perforation by copper intrauterine device.
Eur J Obstet Gynecol Reprod Biol. 1984 Jun;17(4):257-61. doi: 10.1016/0028-2243(84)90068-6.
2
A partial uterine perforation (type 2) by a copper-T IUD: sonographic diagnosis and management.
J Ultrasound Med. 1985 Jul;4(7):381-3. doi: 10.7863/jum.1985.4.7.381.
3
Uterine perforation by a Copper 7 intrauterine contraceptive device with subsequent penetration of the appendix. Case report.
Br J Obstet Gynaecol. 1983 Aug;90(8):774-6. doi: 10.1111/j.1471-0528.1983.tb09310.x.
4
Management of the missing intrauterine contraceptive device: report of a case.
Am J Obstet Gynecol. 1985 Sep 15;153(2):228-9. doi: 10.1016/0002-9378(85)90122-x.
5
The management of intrauterine devices following uterine perforation.
Contraception. 1991 Jan;43(1):77-81. doi: 10.1016/0010-7824(91)90128-3.
6
Laparoscopic removal of translocated intrauterine contraceptives devices.
Br J Obstet Gynaecol. 1982 Feb;89(2):163-5. doi: 10.1111/j.1471-0528.1982.tb04686.x.
7
Postpartum IUDS: keys for success.
Contraception. 1992 Apr;45(4):351-61. doi: 10.1016/0010-7824(92)90057-z.
8
Ultrasonographic evaluation of uterine perforation by an intrauterine device.
J Ultrasound Med. 1982 Nov-Dec;1(9):375. doi: 10.7863/jum.1982.1.9.375.

引用本文的文献

1
An unusual presentation of perforated intrauterine contraceptive device.
Ann Med Health Sci Res. 2013 Apr;3(2):274-6. doi: 10.4103/2141-9248.113678.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验