The effects of two sharpening methods on the strength of a periodontal scaling instrument.

作者信息

Murray G H, Lubow R M, Mayhew R B, Summitt J B, Usseglio R J

出版信息

J Periodontol. 1984 Jul;55(7):410-3. doi: 10.1902/jop.1984.55.7.410.

Abstract

Several different techniques exist for sharpening periodontal scalers each of which will yield a relatively sharp instrument; however, some techniques may decrease the strength of the instrument more rapidly than others. The purpose of this study was to evaluate the effect of two different sharpening techniques on the strength of a periodontal scaler. Sixty McCall No. 13-14 scalers (SCI-DENT) were divided into groups of ten. Each group was reduced in size from 0 to 50% of a standard original size in increments of 10% by reducing the face of the instrument using an RX Honing Machine. A second set of 60 scalers was treated in a similar fashion by reducing the lateral surfaces of the instrument. Original angles and blade clearances were maintained on all instruments. Strength was measured by applying a force at a positive rake angle of 15 degrees in an Instron Testing Machine with a head speed of 50 cm/min. There were no significant differences in strength from grinding on the face vs. the lateral surfaces of the scaler in contrast to the observations of other investigators. Moreover, a 10 to 20% reduction can be accomplished before a significant drop in strength is observed by sharpening either the side or face of the instrument.

摘要

相似文献

1
The effects of two sharpening methods on the strength of a periodontal scaling instrument.
J Periodontol. 1984 Jul;55(7):410-3. doi: 10.1902/jop.1984.55.7.410.
2
The sharpening of scaling instruments: I. An examination of principles.
J Periodontol. 1977 Mar;48(3):163-8. doi: 10.1902/jop.1977.48.3.163.
3
The sharpening of scaling instruments: II. A preferred technique.
J Periodontol. 1977 Mar;48(3):169-72. doi: 10.1902/jop.1977.48.3.169.
4
Preliminary investigation into the performance of a sonic scaler.
J Periodontol. 1987 Nov;58(11):780-4. doi: 10.1902/jop.1987.58.11.780.
7
Effect of the dentin cleansing techniques on dentin wetting and on the bond strength of a resin luting agent.
J Prosthet Dent. 2005 Oct;94(4):363-9. doi: 10.1016/j.prosdent.2005.07.009.
9
[A polishing jig: an aid for the sharpening of scaling instruments].
Tandlakartidningen. 1983 Oct 15;75(20):1092-3, 1096-7.
10
Assessing significance of sharpening brand-new scaler.
Bull Tokyo Dent Coll. 2013;54(1):1-8. doi: 10.2209/tdcpublication.54.1.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验