Suppr超能文献

[基于微处理器技术的新型食管内pH值长时间监测(24小时)仪器的介绍]

[Presentation of a new instrument for the prolonged monitoring (24 hrs.) of endoesophageal pH, based on microprocessor technologies].

作者信息

Zaninotto G, Merigliano S, Baessato M, Nosadini A, Sorrentino P, Pianalto S, Ancona E

出版信息

Minerva Med. 1984 Oct 13;75(39):2301-4.

PMID:6504393
Abstract

Prolonged monitoring of oesophageal pH is the most sensitive test for GOR. An ideal instrument for this test should be simple, reliable and inexpensive. It should enable the patient to live a normal life, even at home, allows rapid analysis of the data, and monitors other parameters at the same time (intragastric pH). An instrument with these features has been devised at Padua University Surgical Clinic. It uses NSC 800 microprocessor technology and has a 32 K C-MOS memory. The examination can be programmed (patient code, date, start and end times, sampling duration and time). Postural changes are automatically recorded. Subjective symptoms are signalled by the patient through an alphanumeric keyboard. ROM software at the end of the test is employed for automatic processing according to Johnson and De Meester's parameters. Proxima is also made for a serial output to a larger-capacity computer and an analogue output compatible with a Beckman paper printer.

摘要

食管pH值的长期监测是诊断胃食管反流(GOR)最敏感的检测方法。用于该检测的理想仪器应具备简单、可靠且价格低廉的特点。它应能让患者即使在家中也能正常生活,能够快速分析数据,并同时监测其他参数(胃内pH值)。帕多瓦大学外科诊所设计了一款具备这些特性的仪器。它采用NSC 800微处理器技术,拥有32K的C-MOS内存。该检查可进行编程设置(患者代码、日期、开始和结束时间、采样时长和时间)。姿势变化会自动记录。患者通过字母数字键盘发出主观症状信号。检测结束时,ROM软件会根据约翰逊和德梅斯特的参数进行自动处理。Proxima还配备了用于向大容量计算机进行串行输出以及与贝克曼纸质打印机兼容的模拟输出。