The myoglobin content of heart muscles was examined by the indirect immunoperoxidase method in eight autopsy cases where death was due to electricity. Seven cases showed a considerable release of myoglobin from the myocardial fibers. In experimental comparison, the heart muscles and skeletal muscles from nine cases where death was natural were exposed to electricity, and considerable deletion of myoglobin was also demonstrated. We believe that the findings of ischemia or thermal effects due to electricity were the cause of the release of myoglobin. Because the demonstration of myoglobin is preferable to estimation of the damaged areas of muscles by hematoxylin-eosin staining, this examination may be more advantageous in forensic examination of death by electricity.
采用间接免疫过氧化物酶法对8例电击致死的尸检病例的心肌肌红蛋白含量进行了检测。7例显示心肌纤维中有大量肌红蛋白释放。在实验对照中,对9例自然死亡病例的心肌和骨骼肌进行电击处理,也证实有大量肌红蛋白缺失。我们认为,电击导致的缺血或热效应是肌红蛋白释放的原因。由于肌红蛋白的检测比苏木精-伊红染色估计肌肉损伤面积更可取,因此该检查在电击致死的法医学检验中可能更具优势。