Suppr超能文献

放射性植入物诱导X射线发射技术用于无创测定甲状腺碘含量:实验研究

Radioactive implant induced x-ray emission technique for noninvasive determination of iodine content in thyroid: experimental study.

作者信息

Amano R, Tonami N, Ando A, Hiraki T, Hisada K

出版信息

Int J Appl Radiat Isot. 1984 Feb;35(2):123-7. doi: 10.1016/0020-708x(84)90195-9.

Abstract

A new technique, radioactive implant x-ray emission spectrometry to determine the in vivo iodine content of the human thyroid is proposed. The variations of counting rate and effective excitation efficiencies of I K alpha (28.6 keV) with iodine content, thyroid volume and skin-thyroid distance were studied for the 201Tl source to examine the properties of excitation and photon attenuation. As a result, the gland depth and volume could be estimated from the peak ratios of 30.7 keV/167.6 keV and 28.6 keV/167.6 keV. Using a 1 MBq 201Tl implant source, the detectable minimum iodine concentration found was approximately 70 micrograms/g for 2000 s measuring time in the phantom experiment. The effectiveness of the RIXE technique is discussed. It was concluded that the 201Tl RIXE spectrometry might serve to determine the in vivo iodine content of the human thyroid.

摘要

提出了一种新技术,即放射性植入物X射线发射光谱法来测定人体甲状腺的体内碘含量。研究了201Tl源的计数率和I Kα(28.6 keV)的有效激发效率随碘含量、甲状腺体积和皮肤-甲状腺距离的变化,以研究激发和光子衰减特性。结果,可以从30.7 keV/167.6 keV和28.6 keV/167.6 keV的峰比值估算腺体深度和体积。在体模实验中,使用1 MBq的201Tl植入源,在2000 s测量时间内发现的可检测最低碘浓度约为70微克/克。讨论了RIXE技术的有效性。得出的结论是,201Tl RIXE光谱法可能有助于测定人体甲状腺的体内碘含量。