Sensitive and reproducible analyses were developed for assaying tamoxifen, monohydroxytamoxifen, N-desmethyltamoxifen, metabolite E [trans-1(4-hydroxyphenyl)1,2-diphenylbut-1-ene] and a new metabolite, metabolite Y [trans-1(4-hydroxyethoxyphenyl)-1,2-diphenylbut-1-ene] in human serum using high-performance liquid chromatography (HPLC). Three different systems were developed for specific purposes. All chromatography was performed using serum extracts made with hexane-butanol. Detection was by fluorimetry of phenanthrene derivatives formed by on-stream UV irradiation with a newly described device for post-column irradiation of the HPLC stream. This device may be of use in other HPLC systems requiring post-column photochemical reactions.

摘要

采用高效液相色谱法(HPLC)建立了灵敏且可重复的分析方法,用于测定人血清中的他莫昔芬、单羟基他莫昔芬、N-去甲基他莫昔芬、代谢物E[反式-1-(4-羟基苯基)-1,2-二苯基丁-1-烯]和一种新的代谢物,代谢物Y[反式-1-(4-羟基乙氧基苯基)-1,2-二苯基丁-1-烯]。为特定目的开发了三种不同的系统。所有色谱分析均使用己烷-丁醇制备的血清提取物进行。通过使用一种新描述的用于HPLC流柱后照射的装置进行在线紫外照射形成的菲衍生物的荧光法进行检测。该装置可能适用于其他需要柱后光化学反应的HPLC系统。