• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Repositioning errors in measurement of vertebral attenuation values by computed tomography.

作者信息

Breatnach E, Robinson P J

出版信息

Br J Radiol. 1983 May;56(665):299-305. doi: 10.1259/0007-1285-56-665-299.

DOI:10.1259/0007-1285-56-665-299
PMID:6850211
Abstract

Difficulty in repositioning makes a major contribution to reproducibility errors in measurements of bone mineral by computed tomography (CT). The magnitude of measurement variations arising from incremental movements in each of three directions of displacement and two directions of rotation were investigated using two sections of cadaver spines each including three vertebral bodies. Within the range of variation in position readily attainable by currently available scan plane selection techniques, changes in measured attenuation were small. Estimated variations resulting from compounded errors of different movements averaged 8.3 Hounsfield units for a single vertebra and 4.9 Hounsfield units for three adjacent vertebrae. The largest change in measured attenuation which could be attributed with 95% confidence to repositioning error within the quoted limits of scan plane selection was estimated to be approximately 15HU for a single vertebra and 8HU for three adjacent vertebrae.

摘要

相似文献

1
Repositioning errors in measurement of vertebral attenuation values by computed tomography.
Br J Radiol. 1983 May;56(665):299-305. doi: 10.1259/0007-1285-56-665-299.
2
[Measurement of bone mineral content in trabecular bone of the 3rd lumbar vertebra by computed tomography with phantom for spine].
Nihon Igaku Hoshasen Gakkai Zasshi. 1986 May 25;46(5):659-64.
3
Quantitative computed tomography in measurement of vertebral trabecular bone mass. A modified method.
Acta Radiol. 1988 Nov-Dec;29(6):719-25.
4
Vertebral trabecular bone: comparison of single and dual-energy CT measurements with chemical analysis.
J Comput Assist Tomogr. 1987 May-Jun;11(3):506-15.
5
[Mineral content of the spongiosa of the lumbar spine determined by computer tomography. Normal values for healthy perimenopausal women and their relation to mechanical stress of the vertebral column].
Radiologe. 1988 Apr;28(4):161-5.
6
[Value and limitations of the computed x-ray tomographic measurement of vertebral mineralization].
J Radiol. 1984 Mar;65(3):151-7.
7
Precise measurement of vertebral mineral content using computed tomography.使用计算机断层扫描精确测量椎体矿物质含量。
J Comput Assist Tomogr. 1980 Aug;4(4):493-500. doi: 10.1097/00004728-198008000-00018.
8
Local differences in mineral content in vertebral trabecular bone measured by dual-energy computed tomography.通过双能计算机断层扫描测量的椎骨小梁骨矿物质含量的局部差异。
Acta Radiol. 1989 Jul-Aug;30(4):369-71.
9
[Quantification of bone mineral density at the 3d lumbar vertebra by dual photon absorptiometry in healthy subjects].
Kaku Igaku. 1987 Apr;24(4):469-73.
10
[Evaluation by EMI CT 5005 Scanner of bone mineral contents variations. A proposed skeletal index for clinical use (author's transl)].
Radiol Med. 1979 Jul-Aug;65(7-8):487-93.

引用本文的文献

1
Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom.无需使用外部参考体模,通过计算机断层扫描精确测量椎骨骨密度。
J Digit Imaging. 1989 Feb;2(1):31-8. doi: 10.1007/BF03168013.
2
Bone density measurements.骨密度测量
Calcif Tissue Int. 1991;49 Suppl:S21-3. doi: 10.1007/BF02555082.