人类髋关节的润滑模式。

Modes of lubrication in human hip joints.

作者信息

Roberts B J, Unsworth A, Mian N

出版信息

Ann Rheum Dis. 1982 Jun;41(3):217-24. doi: 10.1136/ard.41.3.217.

Abstract

Cadaveric hip joints were tested in a hip function simulator which subjected the femoral head to a cycle of loading and oscillation similar to that experienced during walking and measured the frictional torque transmitted to the acetabulum. Silicone fluids with viscosities from 10-2 Pa s (pascal second) to 30 Pa s were used as lubricants and the transition from mixed to full fluid film lubrication was observed around 5 x 10(-2) Pa s. Sodium carboxymethylcellulose solutions were also tested at the lower viscosities. Hyaluronidase digestion of samples of synovial fluid caused a significant increase in friction over the control samples. Trypsin digestion had no significant effect. No correlation between compliance of the cartilage and the frictional values was observed.

摘要

在髋关节功能模拟器中对尸体髋关节进行测试,该模拟器使股骨头承受类似于行走时所经历的加载和振荡循环,并测量传递至髋臼的摩擦扭矩。使用粘度范围从10⁻²帕斯卡秒(Pa s)至30 Pa s的硅油作为润滑剂,观察到在约5×10⁻² Pa s时从混合润滑转变为全液膜润滑。还在较低粘度下测试了羧甲基纤维素钠溶液。对滑液样本进行透明质酸酶消化导致摩擦力比对照样本显著增加。胰蛋白酶消化没有显著影响。未观察到软骨顺应性与摩擦值之间的相关性。

相似文献

1
Modes of lubrication in human hip joints.
Ann Rheum Dis. 1982 Jun;41(3):217-24. doi: 10.1136/ard.41.3.217.
2
The tribological behaviour of different clearance MOM hip joints with lubricants of physiological viscosities.
Proc Inst Mech Eng H. 2011 Nov;225(11):1061-9. doi: 10.1177/0954411911419061.
5
Lubrication and cartilage.
J Anat. 1976 Feb;121(Pt 1):107-18.
6
Adaptive multimode lubrication in natural synovial joints and artificial joints.
Proc Inst Mech Eng H. 1998;212(1):23-35. doi: 10.1243/0954411981533791.
8
Asperity lubrication in human joints.
Proc Inst Mech Eng H. 1993;207(4):245-54. doi: 10.1243/PIME_PROC_1993_207_303_02.
9
Comparison of friction and lubrication of different hip prostheses.
Proc Inst Mech Eng H. 2000;214(1):49-57. doi: 10.1243/0954411001535237.
10
Some new evidence on human joint lubrication.
Ann Rheum Dis. 1975 Aug;34(4):277-85. doi: 10.1136/ard.34.4.277.

引用本文的文献

1
An in vitro simulation method for the tribological assessment of complete natural hip joints.
PLoS One. 2017 Sep 8;12(9):e0184226. doi: 10.1371/journal.pone.0184226. eCollection 2017.
2
Synergistic Interactions of a Synthetic Lubricin-Mimetic with Fibronectin for Enhanced Wear Protection.
Front Bioeng Biotechnol. 2017 Jun 28;5:36. doi: 10.3389/fbioe.2017.00036. eCollection 2017.
3
The friction coefficient of shoulder joints remains remarkably low over 24 h of loading.
J Biomech. 2015 Nov 5;48(14):3945-9. doi: 10.1016/j.jbiomech.2015.09.029. Epub 2015 Oct 9.
4
Effects of hyaluronic acid and γ-globulin concentrations on the frictional response of human osteoarthritic articular cartilage.
PLoS One. 2014 Nov 26;9(11):e112684. doi: 10.1371/journal.pone.0112684. eCollection 2014.
7
Hierarchy of stability factors in reverse shoulder arthroplasty.
Clin Orthop Relat Res. 2008 Mar;466(3):670-6. doi: 10.1007/s11999-007-0096-0. Epub 2008 Feb 10.
8
Concentration polarization of hyaluronan on the surface of the synovial lining of infused joints.
J Physiol. 2004 Dec 1;561(Pt 2):559-73. doi: 10.1113/jphysiol.2004.073643. Epub 2004 Oct 7.
9
Effect of intra-articular hyaluronan on pressure-flow relation across synovium in anaesthetized rabbits.
J Physiol. 1995 May 15;485 ( Pt 1)(Pt 1):179-93. doi: 10.1113/jphysiol.1995.sp020722.

本文引用的文献

1
ANTI-TRYPTIC ACTIVITY OF SYNOVIAL FLUID IN PATIENTS WITH VARIOUS TYPES OF ARTHRITIS.
J Clin Invest. 1935 Jan;14(1):124-30. doi: 10.1172/JCI100647.
3
Role of hyaluronic acid in joint lubrication.
Ann Rheum Dis. 1974 Jul;33(4):318-26. doi: 10.1136/ard.33.4.318.
4
The effects of lubrication in hip joint prostheses.
Phys Med Biol. 1978 Mar;23(2):253-68. doi: 10.1088/0031-9155/23/2/004.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验