Leroux les Jardins S, Heligon J P, Ozdemir N, Pasquier N, Le Hoang P
Hôpital des Quinze-Vingts, Paris.
J Fr Ophtalmol. 1995;18(1):45-9.
To determine the tolerance of the corneal endothelium and of the haemato-ocular barrier of phakic highly myopic eyes implanted with an anterior chamber I.O.L.ses.
Twenty-one phakic highly myopic were operated on with a Z.B.A.C.I.O.L. (manufactured by Domilens) by the same surgeon from May 1989 to June 1990. Complete examination including specular microscopy have been performed before surgery and each 6 months and a Laser Flare Cell Meter at 3 years was performed on 14 eyes.
Two eyes of the same patient had to be explanted after surgery for important endothelial cell loss. The 19 others had no complication: no cataract, no loss of endothelial cells, no retinal detachment. 14 eyes examined with a Laser Cell Flare Meter had results within normal limits. So, 19 out of 21 eyes implanted for high myopia with Z.B.A.C.I.O.L. have excellent results 4 years after surgery.
Regarding these results, it seems possible to use this technique again with the new designed Anterior Chamber I.O.L.. Rigorous follow-up of all the implanted eyes is however required.
确定植入前房型人工晶状体的有晶状体高度近视眼的角膜内皮和血眼屏障的耐受性。
1989年5月至1990年6月,同一位外科医生对21例有晶状体高度近视患者行Z.B.A.C.人工晶状体(由多米伦斯公司生产)植入术。术前及术后每6个月进行包括镜面显微镜检查在内的全面检查,对14只眼在3年时进行激光闪烁细胞仪检查。
同一患者的2只眼术后因重要的内皮细胞丢失而必须取出人工晶状体。其他19只眼无并发症:无白内障、无内皮细胞丢失、无视网膜脱离。用激光细胞闪烁仪检查的14只眼结果在正常范围内。因此,21只植入Z.B.A.C.人工晶状体的高度近视眼中有19只在术后4年效果极佳。
基于这些结果,似乎可以再次使用这种技术于新设计的前房型人工晶状体。然而,对所有植入眼需要进行严格的随访。