Suppr超能文献

健康志愿者中两种新型单氟磷酸二钠缓释制剂与非缓释制剂的比较生物利用度研究。

A comparative bioavailability study on two new sustained-release formulations of disodiummonofluorophosphate versus a nonsustained-release formulation in healthy volunteers.

作者信息

Erlacher L, Templ H, Magometschnigg D

机构信息

Department of Internal Medicine III, University of Vienna, Austria/Europe.

出版信息

Calcif Tissue Int. 1995 Mar;56(3):196-200. doi: 10.1007/BF00298609.

Abstract

In 12 healthy volunteers the pharmacokinetic parameters of two new sustained-release formulations of disodiummonofluorophosphate (MFP) (B and C) were compared with those of a nonsustained-release reference preparation (A). This randomized study had a single-dose, triple-cross over design and consisted of 3 trial days separated by a 1-week washout period. Serial blood samples were obtained over a period of 24 hours and 24-hour urine was collected. Serum and urine fluoride concentrations were determined using an ion-sensitive electrode (Orion Research). The results of this study showed a significant reduction of the area under the serum concentration versus time curve (AUC) for the sustained-release formulations (AUC B: 1487 +/- 354 ng/ml x hour, AUC C: 1369 +/- 384 ng/ml x hour) compared with the reference preparation (AUC A: 2374 +/- 652 ng/ml x hour) (B/A: 63%, C/A: 58%) (P < 0.001). Furthermore, the peak serum concentrations of fluoride (Cmax) for B and C (CmaxB: 166 +/- 42 ng/ml, CmaxC: 110 +/- 48 ng/ml) were significantly lower than for A (CmaxA: 380 +/- 77 ng/ml) (P < 0.001). The 24-hour urine fluoride recovery rates were 5.6 +/- 0.7 mg fluoride for A, 3.6 +/- 0.8 mg for B, and 3.2 +/- 1.1 mg for C and corresponded well to the relative fluoride bioavailability, as concluded from the serum fluoride concentration. In conclusion, the sustained-release preparations of MFP led to a decrease of fluoride bioavailability and avoided high peak serum concentrations.

摘要

在12名健康志愿者中,比较了两种新型缓释氟磷酸二钠(MFP)制剂(B和C)与非缓释参比制剂(A)的药代动力学参数。这项随机研究采用单剂量、三交叉设计,包括3个试验日,中间间隔1周的洗脱期。在24小时内采集系列血样,并收集24小时尿液。使用离子敏感电极(奥立龙研究公司)测定血清和尿液中的氟浓度。本研究结果显示,与参比制剂相比,缓释制剂的血清浓度-时间曲线下面积(AUC)显著降低(AUC B:1487±354 ng/ml·小时,AUC C:1369±384 ng/ml·小时)(参比制剂AUC A:2374±652 ng/ml·小时)(B/A:63%,C/A:58%)(P<0.001)。此外,B和C的血清氟峰浓度(Cmax)(CmaxB:166±42 ng/ml,CmaxC:110±48 ng/ml)显著低于A(CmaxA:380±77 ng/ml)(P<0.001)。A的24小时尿氟回收率为5.6±0.7 mg氟,B为3.6±0.8 mg,C为3.2±1.1 mg,与根据血清氟浓度得出的相对氟生物利用度非常吻合。总之,MFP的缓释制剂导致氟生物利用度降低,并避免了血清高浓度峰值。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验