Suppr超能文献

联合静息铊-201/负荷锝-99m-替曲膦单光子发射计算机断层扫描:90分钟方案的可行性和诊断准确性

Combined rest thallium-201/stress technetium-99m-tetrofosmin SPECT: feasibility and diagnostic accuracy of a 90-minute protocol.

作者信息

Mahmood S, Gunning M, Bomanji J B, Gupta N K, Costa D C, Jarritt P H, Swanton H, Ell P J

机构信息

Institute of Nuclear Medicine, University College London Medical School, United Kingdom.

出版信息

J Nucl Med. 1995 Jun;36(6):932-5.

PMID:7769448
Abstract

UNLABELLED

Technetium-99m tetrofosmin is a recently developed compound that clears from background organs rapidly. Tetrofosmin has a good correlation with 201Tl. This study assesses the feasibility and diagnostic accuracy of a combined protocol involving rest 201Tl SPECT and stress imaging with 99mTc-tetrofosmin.

METHODS

Twenty-five patients (23 men, 2 women; aged 36-73 yr) with known coronary artery disease underwent the combined protocol. Twenty minutes after the resting injection of 201Tl, resting SPECT data were acquired using low-energy, high-resolution collimators. A stress test using adenosine infusion combined with low-level dynamic exercise was performed. The stress data were collected 20 min later. The reconstructed vertical long-axis, horizontal long-axis and short-axis slices were analyzed qualitatively. Analysis was carried out using nine segments of the left ventricle. The segments were reported either as fixed or reversible. The results were compared to coronary angiography results.

RESULTS

The sensitivity and specificity for the detection of diseased coronary vessels were 85% and 70% for the left anterior descending territory, respectively, 78% and 71% for the right coronary artery, and 69% and 70% for the left circumflex. Overall, the sensitivity was 80% and the specificity 70%.

CONCLUSION

Combined rest 201Tl/stress 99mTc-tetrofosmin SPECT provides a protocol of short duration which displays similar diagnostic accuracy to a protocol using tetrofosmin as a single agent.

摘要

未标记

锝-99m替曲膦是一种最近研发的化合物,能迅速从背景器官中清除。替曲膦与铊-201具有良好的相关性。本研究评估了静息铊-201单光子发射计算机断层扫描(SPECT)与锝-99m替曲膦负荷显像联合方案的可行性和诊断准确性。

方法

25例已知冠心病患者(23例男性,2例女性;年龄36 - 73岁)接受了该联合方案检查。静注铊-201后20分钟,使用低能高分辨率准直器采集静息SPECT数据。采用腺苷输注联合低水平动态运动进行负荷试验。20分钟后采集负荷数据。对重建的垂直长轴、水平长轴和短轴断层图像进行定性分析。分析采用左心室的9个节段。这些节段报告为固定或可逆。将结果与冠状动脉造影结果进行比较。

结果

检测病变冠状动脉血管时,左前降支区域的敏感性和特异性分别为85%和70%,右冠状动脉为78%和71%,左旋支为69%和70%。总体而言,敏感性为80%,特异性为70%。

结论

静息铊-201/负荷锝-99m替曲膦联合SPECT检查方案用时短,与使用替曲膦单一制剂的方案相比,诊断准确性相似。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验