Stereoselectivity of the TDxADx/FLx Amphetamine/Methamphetamine II amphetamine/methamphetamine immunoassay--response of urine specimens following nasal inhaler use.

作者信息

Poklis A, Moore K A

机构信息

Medical College of Virginia, Richmond 23298-0597.

出版信息

J Toxicol Clin Toxicol. 1995;33(1):35-41. doi: 10.3109/15563659509020213.

Abstract

The TDxADx/FLx Amphetamine/Methamphetamine II fluorescence polarization immunoassay (Abbott Diagnostic) for the detection of amphetamine and methamphetamine in urine was evaluated for stereoselectivity and response to specimens collected following as recommended and double the recommended dose use of Vicks Nasal Inhaler. The assay is calibrated with d-amphetamine, at cutoff concentration of 300 ng/mL for a positive response. Cross-reactivity studies demonstrated a positive result with 1000 ng/mL l-amphetamine, 300 ng/mL d-methamphetamine, and approximately 2000 ng/mL desoxyephedrine. A good correlation was observed between urines obtained following ingestion of d-amphetamine simultaneously analyzed by TDxADx/FLx Amphetamine/Methamphetamine II and gas chromatography/mass spectrometry: r2 = 0.954, N = 100. However, urine obtained following ingestion of racemic methamphetamine showed no correlation between TDxADx/FLx Amphetamine/Methamphetamine II and gas chromatography/mass spectrometry results: r2 = 0.420, N = 28. Urines collected following as recommended use for five consecutive days of Vicks Nasal Inhaler containing l-desoxyephedrine did not yield positive TDxADx/FLx Amphetamine/Methamphetamine II results. Only two urines from a subject using twice the recommended inhaler dose yielded positive TDxADx/FLx Amphetamine/Methamphetamine II results. These urines contained 1560 and 1530 ng/mL desoxyephedrine when analyzed by gas chromatography/mass spectrometry. Greater than recommended use of Vicks Nasal Inhaler may yield false positive TDxADx/FLx Amphetamine/Methamphetamine II results for amphetamine use when calibrated at 300 ng/mL d-amphetamine. If calibrated at 1000 ng/mL, d-amphetamine, the TDxADx/FLx Amphetamine/Methamphetamine II is unlikely to yield false positive results for amphetamine, even following excessive inhaler use.

摘要

对用于检测尿液中苯丙胺和甲基苯丙胺的TDxADx/FLx苯丙胺/甲基苯丙胺II荧光偏振免疫分析法(雅培诊断公司)进行了立体选择性评估,以及对按照推荐剂量和双倍推荐剂量使用维克斯鼻吸入器后采集的样本的反应评估。该分析方法以d-苯丙胺进行校准,阳性反应的截断浓度为300 ng/mL。交叉反应性研究表明,1000 ng/mL的l-苯丙胺、300 ng/mL的d-甲基苯丙胺和约2000 ng/mL的去氧麻黄碱会产生阳性结果。通过TDxADx/FLx苯丙胺/甲基苯丙胺II和气相色谱/质谱法同时分析摄入d-苯丙胺后获得的尿液之间观察到良好的相关性:r2 = 0.954,N = 100。然而,摄入消旋甲基苯丙胺后获得的尿液在TDxADx/FLx苯丙胺/甲基苯丙胺II和气相色谱/质谱法结果之间没有相关性:r2 = 0.420,N = 28。连续五天按照推荐剂量使用含有l-去氧麻黄碱的维克斯鼻吸入器后采集的尿液,TDxADx/FLx苯丙胺/甲基苯丙胺II检测结果未呈阳性。只有一名受试者使用双倍推荐吸入剂量后采集的两份尿液,TDxADx/FLx苯丙胺/甲基苯丙胺II检测结果呈阳性。通过气相色谱/质谱法分析时,这些尿液中去氧麻黄碱的含量分别为1560和1530 ng/mL。当以300 ng/mL的d-苯丙胺进行校准时,过量使用维克斯鼻吸入器可能会导致TDxADx/FLx苯丙胺/甲基苯丙胺II检测苯丙胺使用情况时出现假阳性结果。如果以ng/mL的d-苯丙胺进行校准,即使过量使用吸入器,TDxADx/FLx苯丙胺/甲基苯丙胺II检测苯丙胺时也不太可能产生假阳性结果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验