Vresilovic E J, Hozack W J, Rothman R H
Hospital of the University of Pennsylvania, Philadelphia.
J Arthroplasty. 1994 Apr;9(2):137-41. doi: 10.1016/0883-5403(94)90062-0.
The correlation between preoperative radiographic findings and intraoperative testing for stability was evaluated for 75 cementless femoral components. Fourteen of 45 porous-coated prostheses were unstable. The following radiographic signs were correlated with instability in order of significance: radiolucent lines at the bone-prosthesis interface covering greater than 50% of the porous interface, a distal pedestal, calcar hypertrophy, poor implant-cortical contact, and varus component alignment. Signs consistent with implant stability were good implant-cortical contact, spot welds, and calcar atrophy. Preoperative radiographs have predictive value in assessing the mechanical stability of the cementless femoral component at the time of surgery.
对75个非骨水泥型股骨假体,评估术前影像学表现与术中稳定性测试之间的相关性。45个多孔涂层假体中有14个不稳定。以下影像学征象按显著性顺序与不稳定相关:骨-假体界面的透亮线覆盖多孔界面的50%以上、远端骨桥、股骨距肥大、假体与皮质骨接触不良以及假体内翻对线。与假体稳定性一致的征象是良好的假体与皮质骨接触、点焊和股骨距萎缩。术前X线片在评估手术时非骨水泥型股骨假体的机械稳定性方面具有预测价值。