The adsorption characteristics of insulinotropin, a 31-amino acid peptide, to several different sterilizing filters were investigated in the present report. The 0.2 micron filters used in the study were a Nylon-66 filter, a hydroxyl-modified polyamide (BioInert) filter, a polyvinylidene fluoride (PVDF) filter, and a polyhydroxy-propyl-acrylate-grafted polyvinylidene fluoride (GV) filter. The results indicate a rank ordering of adsorption (low to high) of GV, BioInert, Nylon-66, and PVDF. Based on these results, it is possible to predict the amount of solution which must be passed through the specific filter to saturate the binding sites per unit area.
在本报告中,研究了一种由31个氨基酸组成的肽——促胰岛素分泌素对几种不同除菌过滤器的吸附特性。该研究中使用的0.2微米过滤器包括尼龙66过滤器、羟基改性聚酰胺(生物惰性)过滤器、聚偏二氟乙烯(PVDF)过滤器和聚丙烯酸羟丙酯接枝聚偏二氟乙烯(GV)过滤器。结果表明,吸附顺序由低到高依次为GV、生物惰性、尼龙66和PVDF。基于这些结果,可以预测必须通过特定过滤器以饱和每单位面积结合位点的溶液量。