Suppr超能文献

805纳米二极管激光辐射的软组织研究:接触式探头的热效应及与1064纳米钕钇铝石榴石激光辐射效应的比较。

Soft tissue studies with 805 nm diode laser radiation: thermal effects with contact tips and comparison with effects of 1064 nm Nd:YAG laser radiation.

作者信息

Judy M M, Matthews J L, Aronoff B L, Hults D F

机构信息

Advanced Laser Applications Laboratory, Baylor Research Institute, Dallas, Texas 75226.

出版信息

Lasers Surg Med. 1993;13(5):528-36. doi: 10.1002/lsm.1900130506.

Abstract

This study compares the perioperative depths of thermal coagulation, charring, and incision in rabbit liver, internal anterior abdominal wall skeletal muscle, and abdominal skin and in swine liver and abdominal skin obtained with 805 nm diode laser and 1,064 nm Nd:YAG laser radiation using 300-microns-diameter conical-tip and 1,200-microns-diameter spherical-tip contact fibers by hand. Additionally, the total depth of tissue necrosis surrounding incisions made with both lasers and contact tips is determined 48 hours postoperatively in the three tissues, and healing of the liver and abdominal wall muscle 21 and 35 days postoperatively is assessed histologically. Perioperatively determined charring, coagulation, and incision depth obtained in all tissues with either 805 nm or 1,064 nm laser radiation were sensibly equivalent at equal laser power values for each of the two contact tip shapes tested. At equal laser power values, coagulation depths obtained in rabbit abdominal skin using the 300-microns-diameter conical tip differed significantly (P < or = 0.01) from those values obtained with the 1,200-microns-diameter spherical tip. Incision depths obtained with the two different contact tip shapes at equal laser power settings in the different tissues studied differed in a few instances with no apparent pattern relating to tissue type or laser power. Depth of incisions obtained with both laser and tip types increases in the range of 6-12 w, but plateaus in the range 12-18 w in the tissues studied. Incisions obtained with both diode and Nd:YAG laser contact were essentially hemostatic, with self-limiting oozing at most.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

本研究比较了使用805纳米二极管激光和1064纳米钕:钇铝石榴石激光辐射,通过手工操作300微米直径的圆锥形尖端和1200微米直径的球形尖端接触光纤,在兔肝、腹前壁内部骨骼肌、腹部皮肤以及猪肝和腹部皮肤中进行围手术期热凝、碳化和切开的深度。此外,在术后48小时测定两种激光和接触尖端在这三种组织中造成的切口周围组织坏死的总深度,并在术后21天和35天对肝和腹壁肌肉的愈合情况进行组织学评估。对于所测试的两种接触尖端形状中的每一种,在相同激光功率值下,用805纳米或1064纳米激光辐射在所有组织中围手术期测定的碳化、热凝和切开深度明显相当。在相同激光功率值下,使用300微米直径圆锥形尖端在兔腹部皮肤中获得的热凝深度与使用1200微米直径球形尖端获得的值有显著差异(P≤0.01)。在相同激光功率设置下,用两种不同接触尖端形状在不同研究组织中获得的切开深度在少数情况下有所不同,且与组织类型或激光功率没有明显关联模式。在研究的组织中,使用激光和尖端类型获得的切开深度在6 - 至12瓦范围内增加,但在12 - 18瓦范围内趋于平稳。使用二极管激光和钕:钇铝石榴石激光接触获得的切口基本上能止血,最多有自限性渗血。(摘要截于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验