Griffith D, Nacey J, Robinson R, Delahunt B
Department of Surgery, Wellington School of Medicine, New Zealand.
Aust N Z J Surg. 1993 Mar;63(3):203-4. doi: 10.1111/j.1445-2197.1993.tb00519.x.
A standard household 650 W microwave oven was used to sterilize polyethylene catheters of the type used for intermittent self-catheterization. The catheters were infected with Proteus sp. bacteria and microwaved at 650 W for periods of 2, 4, 6 and 8 minutes. The effect of microwaving was assessed by determining the resultant colony counts following catheter culture. It was determined that 6 minutes of microwaving were required to achieve sterility. It is suggested that use of a microwave oven is a reliable and cost-effective method of sterilizing polyethylene catheters for intermittent self-catheterization.
使用一台标准的家用650瓦微波炉对用于间歇性自我导尿的聚乙烯导管进行消毒。这些导管感染了变形杆菌属细菌,并在650瓦功率下微波处理2、4、6和8分钟。通过测定导管培养后的菌落计数来评估微波处理的效果。结果确定需要微波处理6分钟才能达到无菌状态。有人建议,使用微波炉是一种可靠且经济高效的对用于间歇性自我导尿的聚乙烯导管进行消毒的方法。