[The measurement of superoxide generation and eosinophil peroxidase (EPO) from eosinophils].

作者信息

Okada C, Soda R, Takahashi K

机构信息

National Sanatrium Minami Okayama Hospital.

出版信息

Nihon Rinsho. 1993 Mar;51(3):730-5.

PMID:8388065
Abstract

Eosinophils play an important role in the field of allergy, and release several kinds of granule proteins, leukotrien and superoxide. The most popular method to measure superoxide is utilizing SOD-inhibitable reduction of ferricytochrome c. And recently, the microplate reader enables us to measure superoxide generation from eosinophils more easily using this method. To measure superoxide, we must pay attention to obtain a high purity of eosinophils and not to damage cells. It is also possible to measure eosinophil peroxidase (EPO) using the microplate reader. We are measuring EPO with colorimetric assay using OPD (o-phenylenediamine). OPD is specific to EPO and has no cross reaction to myeloperoxidase. We, now have numerous methods to evaluate eosinophil function, so a selection must be made to select the most correct method.