Suppr超能文献

The selection of wires for sublaminar fixation.

作者信息

Boeree N R, Dove J

机构信息

Stoke-on-Trent Spinal Service, Hartshill Orthopaedic Hospital, England.

出版信息

Spine (Phila Pa 1976). 1993 Mar 15;18(4):497-503.

PMID:8470012
Abstract

The authors report a comparative biomechanical study of the suitability of four types of stainless steel wire for sublaminar fixation. Tensile and fatigue tests were performed on wires in the configuration used at surgery. They conclude that annealed 18-gauge (1.2 mm) wire should be used at each end of a scoliosis fusion, at the upper end of a lumbar fusion, and throughout for thoracolumbar fractures. Cold-worked 20-gauge (0.87 mm) wire may be used in all other situations, but the use of annealed 20-gauge wire should be restricted to the cervical spine. The authors emphasize the importance of achieving the correct balance between wire stiffness and flexibility, of care in the handling of wires, and of proper technique in achieving secure fixation.

摘要

相似文献

1
The selection of wires for sublaminar fixation.
Spine (Phila Pa 1976). 1993 Mar 15;18(4):497-503.
3
Cobalt chromium sublaminar wires for spinal deformity surgery.
Spine (Phila Pa 1976). 2006 Sep 1;31(19):2209-12. doi: 10.1097/01.brs.0000232817.32764.a7.
4
A biomechanical study of wire fixation.
Can J Surg. 1987 Jan;30(1):51-2.
5
A biomechanical analysis of sublaminar and subtransverse process fixation using metal wires and polyethylene cables.
Spine (Phila Pa 1976). 2006 Sep 1;31(19):2202-8. doi: 10.1097/01.brs.0000232831.63589.22.
6
The use of sublaminar cables to replace Luque wires.
Spine (Phila Pa 1976). 1991 Aug;16(8 Suppl):S418-21.
7
Comparative mechanical properties of spinal cable and wire fixation systems.
Spine (Phila Pa 1976). 1997 Mar 15;22(6):596-604. doi: 10.1097/00007632-199703150-00004.
8
Fracture analysis of retrieved orthopedic wires.
J Biomed Mater Res. 1986 Sep;20(7):887-94. doi: 10.1002/jbm.820200704.
9
Segmental spinal instrumentation using short closed wire loops.
Clin Orthop Relat Res. 1989 Oct(247):90-6.
10
The fatigue resistance of orthopaedic wire.
Clin Orthop Relat Res. 1985 Jan-Feb(192):228-36.

引用本文的文献

1
Image classification of osteoporotic vertebral fracture with endplate-disc complex Injury.
BMC Musculoskelet Disord. 2021 Feb 17;22(1):197. doi: 10.1186/s12891-021-04070-6.
2
The Use of Metal Sublaminar Wires in Modern Growth-Guidance Scoliosis Surgery: A Report of 4 Cases and Literature Review.
Int J Spine Surg. 2020 Apr 30;14(2):182-188. doi: 10.14444/7017. eCollection 2020 Apr.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验