Chung K C, Wilkins E G, Beil R J, Helvie M A, Ikeda D M, Oneal R M, Forrest M E, Smith D J
Section of Plastic Surgery, University of Michigan, Ann Arbor, USA.
Plast Reconstr Surg. 1996 Jan;97(1):104-9. doi: 10.1097/00006534-199601000-00017.
To prospectively evaluate the efficacy of ultrasonography in the diagnosis of ruptured silicone gel breast implants, 98 patients (192 implants) underwent preoperative breast ultrasonography prior to silicone gel breast implant removal. The prevalence of implant rupture confirmed at surgery in this group of patients was 62 of the 192 implants (32 percent). Of the 60 implants diagnosed as ruptured by ultrasonography, 46 were confirmed as having visible defects at surgery (true positive) for a positive predictive value of 77 percent. Of the 132 implants diagnosed as intact by ultrasonography, 116 were confirmed as intact at surgery (true negative) for a negative predictive value of 88 percent. Overall, the sensitivity of ultrasonography for implant rupture was 74 percent, and the specificity was 89 percent. These findings demonstrate that ultrasonography is an effective imaging modality for the diagnosis of silicone gel breast implant rupture. Compared with mammography, ultrasonography appears to offer superior sensitivity and specificity without radiation exposure or discomfort. Although magnetic resonance imaging has shown considerable promise in the diagnosis of implant rupture, ultrasonography provides comparable sensitivity at a fraction of MRI's cost.
为前瞻性评估超声检查在诊断硅胶乳房植入物破裂中的疗效,98例患者(192个植入物)在取出硅胶乳房植入物之前接受了术前乳房超声检查。在该组患者中,手术中证实的植入物破裂发生率为192个植入物中的62个(32%)。在超声检查诊断为破裂的60个植入物中,46个在手术中被证实有可见缺陷(真阳性),阳性预测值为77%。在超声检查诊断为完整的132个植入物中,116个在手术中被证实完整(真阴性),阴性预测值为88%。总体而言,超声检查对植入物破裂的敏感性为74%,特异性为89%。这些发现表明,超声检查是诊断硅胶乳房植入物破裂的一种有效成像方式。与乳腺摄影相比,超声检查似乎具有更高的敏感性和特异性,且无辐射暴露或不适。虽然磁共振成像在诊断植入物破裂方面显示出很大前景,但超声检查以MRI成本的一小部分提供了相当的敏感性。