Fitoussi F, Ip W Y, Chow S P
Department of Orthopaedic Surgery, University of Hong Kong, Queen Mary Hospital, Hong Kong.
J Hand Surg Br. 1996 Dec;21(6):760-4. doi: 10.1016/s0266-7681(96)80182-3.
The mechanical rigidity obtained by external fixation in a comminuted phalangeal fracture model was assessed and the results compared with two other types of internal fixation commonly used (lateral plate and crossed Kirschner wires) in a biomechanical cadaver study. Each fixation technique was tested in apex palmar bending, compression and torsion. The results showed that lateral plating provided the best rigidity in apex palmar bending and compression and that external fixation and Kirschner wires showed the same mechanical properties. For the torque test, external fixation provided the best rigidity.
在一个粉碎性指骨骨折模型中,评估了通过外固定获得的机械刚度,并在一项生物力学尸体研究中,将结果与另外两种常用的内固定类型(外侧钢板和交叉克氏针)进行了比较。每种固定技术都在掌侧顶端弯曲、压缩和扭转试验中进行了测试。结果表明,外侧钢板固定在掌侧顶端弯曲和压缩时提供了最佳的刚度,外固定和克氏针表现出相同的力学性能。在扭矩测试中,外固定提供了最佳的刚度。