Small J H, Dixon A K, Coulden R A, Flower C D, Housden B A
Department of Radiology, Addenbrooke's Hospital NHS Trust, UK.
Br J Radiol. 1996 Oct;69(826):900-5. doi: 10.1259/0007-1285-69-826-900.
Results were evaluated in 81 patients with suspected acute aortic dissection who were examined on a fast CT system capable of a 1 s data acquisition time. 17 patients had Type A and nine had Type B dissections. Radiological assessment provided 78 confident reports and expressed some uncertainty about the diagnosis in three patients. Overall sensitivity for aortic dissection was 96.2% and specificity was 96.4%. When 78 confident reports alone were considered, both sensitivity and specificity reached 100%. Reconstruction of data at 100 ms intervals allowed discrimination between artefacts in the ascending aorta and Type A dissections. CT can often be used as the single investigation prior to surgery for acute Type A dissections.
对81例疑似急性主动脉夹层的患者进行了评估,这些患者在能够在1秒内完成数据采集的快速CT系统上接受了检查。17例为A型夹层,9例为B型夹层。放射学评估给出了78份肯定的报告,对3例患者的诊断表示了一些不确定性。主动脉夹层的总体敏感性为96.2%,特异性为96.4%。仅考虑78份肯定报告时,敏感性和特异性均达到100%。以100毫秒的间隔重建数据能够区分升主动脉中的伪影和A型夹层。对于急性A型夹层,CT通常可作为手术前的单一检查手段。