Sharpe J R, Sammons R L, Marquis P M
Biomaterials Unit, School of Dentistry, University of Birmingham, UK.
Biomaterials. 1997 Mar;18(6):471-6. doi: 10.1016/s0142-9612(96)00157-3.
Calcium phosphate ceramics used for clinical applications vary considerably in their phase composition. A range of hydroxyapatite and tricalcium phosphate powders, some of which are used in plasma-sprayed coatings for metal prostheses, were found to leach substances which change the pH of water and cell culture medium. The adsorption of serum proteins from cell culture medium to the same hydroxyapatite and tricalcium phosphate ceramics was compared by sodium dodecyl sulphate-polyacrylamide gel electrophoresis and individual bands identified by enhanced chemiluminescence immunodetection and gas chromatography sequencing. The iron transport protein transferrin showed distinct differences in adsorption to a variety of hydroxyapatite and tricalcium phosphate powders, with higher concentrations of transferrin adsorbed to powders which caused no change or a drop in the pH of cell culture medium or water. Transferrin was also adsorbed to Biotal HA 120 in greater concentrations at a lower pH than it was at a higher pH. These preliminary studies show that pH changes brought about by the leaching of soluble ions may have an effect on protein adsorption.
用于临床的磷酸钙陶瓷在相组成上有很大差异。一系列羟基磷灰石和磷酸三钙粉末,其中一些用于金属假体的等离子喷涂涂层,被发现会浸出改变水和细胞培养基pH值的物质。通过十二烷基硫酸钠-聚丙烯酰胺凝胶电泳比较了细胞培养基中血清蛋白对相同羟基磷灰石和磷酸三钙陶瓷的吸附情况,并通过增强化学发光免疫检测和气相色谱测序鉴定了各个条带。铁转运蛋白转铁蛋白在吸附到各种羟基磷灰石和磷酸三钙粉末上时表现出明显差异,转铁蛋白在导致细胞培养基或水的pH值不变或下降的粉末上吸附浓度更高。在较低pH值下,转铁蛋白在Biotal HA 120上的吸附浓度也高于较高pH值时。这些初步研究表明,可溶性离子浸出引起的pH值变化可能会对蛋白质吸附产生影响。