Goh J, Thambyah A, Noor Ghani A, Bose K
Department of Orthopaedic Surgery National University of Singapore, Singapore.
Injury. 1997 Jan;28(1):29-34. doi: 10.1016/s0020-1383(96)00149-0.
Simple external fixation is becoming ever more popular for the treatment of fractures. Current commercially available external fixation devices are complex and expensive, affecting management of injuries in less developed countries. In this study, a new simple and low-cost external fixator called the AG (Alinoor-Goh) fixator, is evaluated biomechanically by direct comparison with a commercially available fixator device (AO). Four modes of loading were applied to each of the fixators: axial compression, anterior-posterior bending, medial-lateral bending, and torsion. The loads were applied directly onto a fractured-bone model made of perspex, which was immobilized by the fixator through six Schanz pins. From this, stiffness values were obtained by plotting load versus displacement. The results from the mechanical testing indicated that in axial compression the AG fixator stiffness was 55.7 +/- 0.197 N/mm (AO fixator was 57.7 +/- 0.186 N/mm); for anterior-posterior bending it was 56.8 +/- 0.153 N/mm (57.4 +/- 0.134 N/mm); for medial-lateral bending it was 11.4 +/- 0.036 N/mm (11.6 +/- 0.053 N/mm); and for torsion it was 1.16 +/- 0.002 N.mm/degree (1.16+/- 0.003 N.mm/degree). No significant difference was found in the stiffness of AG and AO fixators, under all modes of loading. A further comparison in terms of overall design, versatility in application and cost shows the AG fixator to be a viable, inexpensive option for the treatment of long-bone fractures.
简单外固定在骨折治疗中越来越受欢迎。目前市面上的外固定装置复杂且昂贵,这影响了欠发达国家的创伤治疗。在本研究中,一种名为AG(阿利努尔-戈)固定器的新型简单且低成本的外固定器,通过与一种市售固定器装置(AO)直接比较进行了生物力学评估。对每个固定器施加了四种加载模式:轴向压缩、前后弯曲、内外侧弯曲和扭转。载荷直接施加在由有机玻璃制成的骨折骨模型上,该模型通过六个斯氏针由固定器固定。由此,通过绘制载荷与位移的关系图获得刚度值。力学测试结果表明,在轴向压缩中,AG固定器的刚度为55.7±0.197N/mm(AO固定器为57.7±0.186N/mm);在前后弯曲中为56.8±0.153N/mm(57.4±0.134N/mm);在内外侧弯曲中为11.4±0.036N/mm(11.6±0.053N/mm);在扭转中为1.16±0.002N·mm/度(1.16±0.003N·mm/度)。在所有加载模式下,AG和AO固定器的刚度均未发现显著差异。在整体设计、应用的通用性和成本方面的进一步比较表明,AG固定器是治疗长骨骨折的一种可行且廉价的选择。