Suppr超能文献

放射性标记的二乙三胺五乙酸肺扫描在卡氏肺孢子虫肺炎和无症状HIV阳性患者中的应用

Radioactively labelled diethylene triamine penta acetate lung scan in Pneumocystis carinii pneumonia and asymptomatic HIV-positive patients.

作者信息

Dimian C O, O'Doherty M J, Asboe D, Page C J, Entwisle K, Bingham J S

机构信息

Department of Genito-Urinary Medicine, St Thomas' Hospital, London, UK.

出版信息

Int J STD AIDS. 1997 Aug;8(8):482-8. doi: 10.1258/0956462971920622.

Abstract

The objective of this study is to establish normal ranges for the assessment of lung permeability, using 99mTc DTPA (diethylene triamine penta acetate) aerosol by measuring the half-time of transfer from the lung in asymptomatic HIV-positive patients. Also to audit the use of the test in the clinical management of outpatients with symptoms suggestive of Pneumocystis carinii pneumonia (PCP). A retrospective analysis of data from outpatients' notes for the audit of symptomatic patients, and prospective acquisition of 'normal' data for HIV-positive asymptomatic patients who were non-smokers and smokers was performed. Over a period of 8 years, DTPA scans were performed on 400 asymptomatic HIV-positive patients (121 non-smokers and 279 smokers) and 188 symptomatic HIV-positive patients with symptoms suggestive of PCP. A biphasic curve of transfer of 99mTc DTPA with a half-time of less than 4 min, was considered diagnostic of PCP. The mean half-times (+/-SEM) for asymptomatic non-smokers was 61.4 +/- 3 min and for smokers was 21.9 +/- 0.8 min. In the symptomatic patients, 106 were treated for PCP and in 97 (91.5%) of these, the transfer was biphasic. Of the remaining 82 patients with respiratory pathology other than PCP, 71 (86.6%) had normal scans. The results show that smokers may have abnormal baseline scans 16/ 279 (5.7%) and therefore a baseline scan before symptoms should be recorded or a higher false positive rate can be expected. The test is however highly sensitive for the detection of PCP and allows the attending physician to initiate PCP treatment without delay.

摘要

本研究的目的是通过测量无症状HIV阳性患者肺部99mTc DTPA(二乙烯三胺五乙酸)气雾剂的转运半衰期,建立评估肺通透性的正常范围。同时审核该检测方法在疑似卡氏肺孢子虫肺炎(PCP)症状的门诊患者临床管理中的应用情况。对有症状患者进行回顾性分析,收集门诊病历数据用于审核,对非吸烟和吸烟的无症状HIV阳性患者进行前瞻性“正常”数据采集。在8年时间里,对400例无症状HIV阳性患者(121例非吸烟者和279例吸烟者)以及188例有疑似PCP症状的有症状HIV阳性患者进行了DTPA扫描。99mTc DTPA转运的双相曲线且半衰期小于4分钟被认为是PCP的诊断标准。无症状非吸烟者的平均半衰期(±标准误)为61.4±3分钟,吸烟者为21.9±0.8分钟。在有症状患者中,106例接受了PCP治疗,其中97例(91.5%)的转运为双相。其余82例患有除PCP之外的呼吸道疾病的患者中,71例(86.6%)扫描结果正常。结果表明,吸烟者可能有异常的基线扫描结果(279例中有16例,占5.7%),因此应记录症状出现前的基线扫描结果,否则可能会出现较高的假阳性率。然而,该检测方法对PCP的检测具有高度敏感性,可使主治医生及时开始PCP治疗。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验