Tucker D M, Suitor C T, Shepard S J, Schomer D F
Division of Diagnostic Imaging, University of Texas M.D. Anderson Cancer Center, Houston 77096, USA.
J Digit Imaging. 1997 Aug;10(3):120-5. doi: 10.1007/BF03168599.
Large-scale picture archiving and communication systems (PACS) have not been widely implemented in this or other countries. In almost all radiology departments film remains the medium for diagnostic interpretation and image archive. Chest imaging is the dominant screening examination performed within most imaging departments and as such, is an extremely high-volume, low-margin examination. Digital technologies are being applied to chest imaging to overcome limitations of screen-film receptors (limited latitude) and current film management systems (single-image copy). Efficient management of images and information is essential to the success of a chest imaging program. In this article we report on a digital imaging and communications in medicine (DICOM)-based centralized printing network for chest imaging. The system components and their operational characteristics are described. Our experience integrating DICOM-compliant equipment supplied by several vendors is described. We conclude that the print model supported by DICOM is adequate for cross-sectional (eg, computed tomography and magnetic resonance) imaging but is too simplistic to be generally applied to projection radiography.
大型图像存档与通信系统(PACS)在本国或其他国家尚未得到广泛应用。在几乎所有放射科,胶片仍是用于诊断解读和图像存档的媒介。胸部成像在大多数影像科室的筛查检查中占主导地位,因此是一项工作量极大、利润微薄的检查。数字技术正被应用于胸部成像,以克服屏-片接收器(宽容度有限)和当前胶片管理系统(单图像拷贝)的局限性。图像和信息的高效管理对于胸部成像项目的成功至关重要。在本文中,我们报告了一种基于医学数字成像和通信(DICOM)的胸部成像集中打印网络。描述了系统组件及其运行特性。阐述了我们整合多家供应商提供的符合DICOM标准设备的经验。我们得出结论,DICOM支持的打印模式适用于断层成像(如计算机断层扫描和磁共振成像),但过于简单,无法普遍应用于投影放射成像。