Suppr超能文献

螺旋扫描的非平稳噪声特性及其对图像质量和伪影的影响。

Nonstationary noise characteristics of the helical scan and its impact on image quality and artifacts.

作者信息

Hsieh J

机构信息

Applied Science Laboratory, G.E. Medical Systems, Milwaukee, Wisconsin 53201, USA.

出版信息

Med Phys. 1997 Sep;24(9):1375-84. doi: 10.1118/1.598026.

Abstract

Helical computed tomography has replaced the conventional step-and-shoot CT in many clinical applications. Because of its clinical importance, a number of comparative studies have been performed to evaluate its performance parameters, such as the noise and the slice sensitivity profile. In this paper, the nonstationary noise characteristics of helical images are carefully examined. Their impact on the low contrast detectability and three-dimensional (3-D) image artifacts is assessed. An analytical equation is derived to relate the interactions between various helical reconstruction schemes and the fan-beam filtered backprojection algorithm. We demonstrate that for many popular helical weights, the noise variation within the field of view of the reconstruction is close to a factor of 3. Several approaches to overcome the undesired characteristics are proposed.

摘要

螺旋计算机断层扫描在许多临床应用中已取代了传统的步进式CT。由于其临床重要性,已经进行了多项比较研究来评估其性能参数,如噪声和切片灵敏度分布。在本文中,我们仔细研究了螺旋图像的非平稳噪声特性。评估了它们对低对比度可探测性和三维(3-D)图像伪影的影响。推导了一个解析方程,以关联各种螺旋重建方案与扇束滤波反投影算法之间的相互作用。我们证明,对于许多常用的螺旋权重,重建视野内的噪声变化接近3倍。提出了几种克服这些不良特性的方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验