Kapadia F, Rodrigues C, Jha A N
P. D. Hinduja National Hospital and Medical Research Centre, Veer Savarkar Marg, Mahim Bombay, India.
Br J Neurosurg. 1997 Aug;11(4):335-6. doi: 10.1080/02688699746122.
Infection of intracranial catheters is a common complication of ICP monitoring. The introduction of a simple technique of ensheathing the entire length of the external segment of the catheter in a sterile plastic sheath resulted in a decreased infection rate. In the study year, one of 78 patients developed catheter-induced meningitis, compared with seven of 64 patients in the year prior to the introduction of the protective plastic sheath. The use of a plastic sheath resulted in a low rate of infection.
颅内导管感染是颅内压监测常见的并发症。采用一种简单的技术,即将导管外部段的全长套入无菌塑料鞘内,可降低感染率。在研究当年,78例患者中有1例发生导管相关性脑膜炎,而在引入保护性塑料鞘之前的一年中,64例患者中有7例发生。使用塑料鞘导致感染率较低。