Ali M, Nairn R I, Sherriff M, Waters N E
Department of Prosthetic Dentistry, UMDS, Guy's Dental School, London, England.
J Prosthet Dent. 1997 Oct;78(4):419-24. doi: 10.1016/s0022-3913(97)70052-0.
This in vitro study examined the distortion of 10 identically designed cast cobalt-chromium alloy frameworks, individually constructed, and adjusted by 10 technicians to fit one of 10 replicated stone working casts.
The distortion was measured with a specially developed strain gauge apparatus when the frameworks were seated on the maxillary metal analog, the stone working cast, or a stone duplicate cast.
A statistically significant difference between the distortion of each of the frameworks was observed. A significant difference in the distortion was also observed for the frameworks when placed on each of the three casts. The distortion was the least when the frameworks were seated on the stone working cast and the greatest when seated on the metal analog.
This study demonstrated that the distortion of a framework is not related to its closeness of fit as observed by the presence or absence of gaps between the framework components and the teeth.
本体外研究检测了10个设计相同的铸造钴铬合金支架的变形情况,这些支架由10名技术人员分别制作并调整,以适配10个复制的石膏工作模型中的一个。
当支架就位在上颌金属代型、石膏工作模型或石膏复制模型上时,使用专门开发的应变仪测量变形情况。
观察到每个支架的变形情况存在统计学上的显著差异。当支架放置在三种模型中的每一种上时,变形情况也存在显著差异。支架就位在石膏工作模型上时变形最小,就位在金属代型上时变形最大。
本研究表明,支架的变形与其适配紧密程度无关,这可通过观察支架部件与牙齿之间是否存在间隙来判断。