Suppr超能文献

AMO阵列多焦点与单焦点人工晶状体:长期随访

AMO array multifocal versus monofocal intraocular lenses: long-term follow-up.

作者信息

Vaquero-Ruano M, Encinas J L, Millan I, Hijos M, Cajigal C

机构信息

Ophthalmology Department, Puerto de Hierro University Clinic, Madrid, Spain.

出版信息

J Cataract Refract Surg. 1998 Jan;24(1):118-23. doi: 10.1016/s0886-3350(98)80084-9.

Abstract

PURPOSE

To assess prospectively the visual outcomes of multifocal and monofocal intraocular lens (IOL) implantation in selected patients with a minimum follow-up of 18 months.

SETTING

Department of Ophthalmology, National Health Service (INSALUD). Puerta de Hierro University Clinic, Madrid, Spain.

METHODS

This prospective study comprised two groups of 50 eyes each: one with AMO Array multifocal IOLs and the other with monofocal IOLs. Main outcome measures were Snellen and Regan 96% distance visual acuities; Jaeger and decimal near acuities; Regan contrast sensitivity test at 96, 50, 25, and 11%; brightness acuity test (BAT) on distance acuity at Regan 96%; depth of focus measured with the Regan 96% distance test; defocusing from +3s to -4s; subjective evaluation of optical side effects.

RESULTS

The differences between groups in mean distance vision and BAT results were not statistically significant Contrast sensitivity results at 96 and 50% were similar, but there were significant differences of 0.94 and 1.14 lines on the 25 and 11% charts, respectively (P < .01). Near vision without addition in the multifocal group was significantly better and depth of focus significantly wider than in the monofocal group (P < .001).

CONCLUSION

With appropriate patient selection, the AMO Array IOL provided distance acuity and contrast sensitivity similar to that of the monofocal IOLs and excellent intermediate vision. Near vision, without spectacles, with the multifocal lens was functionally acceptable although short of refractive power for best acuity results.

摘要

目的

对选定患者进行多焦点和单焦点人工晶状体(IOL)植入的视觉效果进行前瞻性评估,至少随访18个月。

设置

西班牙马德里Puerta de Hierro大学诊所国家卫生服务局(INSALUD)眼科。

方法

这项前瞻性研究包括两组,每组50只眼:一组植入AMO Array多焦点IOL,另一组植入单焦点IOL。主要观察指标包括Snellen和Regan 96%远视力;Jaeger和小数近视力;96%、50%、25%和11%时的Regan对比敏感度测试;Regan 96%时远视力的亮度视力测试(BAT);用Regan 96%远视力测试测量的焦深;从+3s到-4s的散焦;光学副作用的主观评估。

结果

两组在平均远视力和BAT结果上的差异无统计学意义。96%和50%时的对比敏感度结果相似,但在25%和11%的图表上分别有0.94和1.14行的显著差异(P < 0.01)。多焦点组无附加镜的近视力明显优于单焦点组,焦深也明显更宽(P < 0.001)。

结论

通过适当的患者选择,AMO Array IOL提供的远视力和对比敏感度与单焦点IOL相似,且具有出色的中间视力。多焦点镜片的无眼镜近视力在功能上是可以接受的,尽管屈光力不足,无法获得最佳视力结果。