Suppr超能文献

丝裂霉素C对小梁切除术及三联手术术后角膜散光的影响。

The effect of mitomycin-C on postoperative corneal astigmatism in trabeculectomy and a triple procedure.

作者信息

Hong Y J, Choe C M, Lee Y G, Chung H S, Kim H K

机构信息

Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea.

出版信息

Ophthalmic Surg Lasers. 1998 Jun;29(6):484-9.

PMID:9640570
Abstract

BACKGROUND AND OBJECTIVE

The authors attempted to determine the effect of mitomycin-C (MMC) on postoperative corneal astigmatism in patients who underwent trabeculectomy or a triple procedure (trabeculectomy, extracapsular cataract extraction, and intraocular lens implantation).

PATIENTS AND METHODS

Using the vector analysis method, the authors measured the postoperative induced astigmatism of 76 eyes in 59 patients who underwent trabeculectomy or a triple procedure with or without the application of MMC. Postoperative induced astigmatism corresponding to the 180 degrees axis was compared between the two groups.

RESULTS

The patients who underwent trabeculectomy with or without MMC showed a mean induced astigmatism of -1.01 D and -2.63 D, respectively, after 1 month (P < .05), and 0.34 D and -1.42 D after 12 months (P < .05). Those who underwent a triple procedure with or without MMC showed a mean induced astigmatism of -1.81 D and -4.50 D, respectively, after 7 days (P < .05), and 1.73 D and -0.13 D, respectively, after 12 months (P < .05). The entire amount of postoperative against-the-rule astigmatic shift was similar between the with-MMC group and the without-MMC group. The against-the-rule astigmatic shift of the group without MMC reached a plateau after 3 months. However, the group with MMC showed continuous against-the-rule astigmatic shift until 12 months.

CONCLUSION

This study suggests that MMC induces less with-the-rule astigmatism in early postoperative periods and continuous against-the-rule shift after 3 months following a trabeculectomy or a triple procedure.

摘要

背景与目的

作者试图确定丝裂霉素-C(MMC)对接受小梁切除术或三联手术(小梁切除术、白内障囊外摘除术和人工晶状体植入术)患者术后角膜散光的影响。

患者与方法

作者采用矢量分析方法,测量了59例接受小梁切除术或三联手术且使用或未使用MMC的患者76只眼的术后诱导散光。比较了两组对应180度轴的术后诱导散光。

结果

接受小梁切除术使用或未使用MMC的患者,术后1个月平均诱导散光分别为-1.01 D和-2.63 D(P < 0.05),术后12个月分别为0.34 D和-1.42 D(P < 0.05)。接受三联手术使用或未使用MMC的患者,术后7天平均诱导散光分别为-1.81 D和-4.50 D(P < 0.05),术后12个月分别为1.73 D和-0.13 D(P < 0.05)。MMC组和未使用MMC组术后逆规散光移位总量相似。未使用MMC组的逆规散光移位在3个月后达到平台期。然而,使用MMC组在术后12个月前持续出现逆规散光移位。

结论

本研究表明,MMC在小梁切除术或三联手术后早期诱导的顺规散光较少,且在术后3个月后持续出现逆规散光移位。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验