Delaunay C P, Kapandji A I
Clinique de l'Yvette, Longjumeau, France.
Acta Orthop Scand. 1998 Aug;69(4):379-83. doi: 10.3109/17453679808999050.
We studied prospectively 382 cementless (Zweymüller stem) and hybrid (cemented stem) primary total hip replacements and used a cementless grit-blasted titanium alloy threaded cup. After a median 5 (0.2-12) year follow-up, 1 cup was exchanged, 2 cups were removed for deep sepsis, and 3 cups showed definite loosening; of these, 2 subsequently required revision. Actuarial calculation methods indicated a 10-year survivorship of 99% with cup retrieval for any cause (clinical failure), definite cup-loosening (radiographic failure), and revision for aseptic cup-loosening as endpoints. These intermediate results exceed those from smooth-surfaced screw rings and compare favorably with those from cemented cups and cementless, press-fit, metal-backed cups.
我们前瞻性地研究了382例非骨水泥型(Zweymüller柄)和混合型(骨水泥柄)初次全髋关节置换术,并使用了非骨水泥型喷砂处理的钛合金带螺纹髋臼杯。经过中位时间5(0.2 - 12)年的随访,1个髋臼杯进行了翻修,2个髋臼杯因深部脓毒症被取出,3个髋臼杯出现明确松动;其中2个随后需要进行翻修。精算计算方法表明,以因任何原因(临床失败)取出髋臼杯、明确的髋臼杯松动(影像学失败)以及因无菌性髋臼杯松动进行翻修为终点,10年生存率为99%。这些中期结果超过了光滑表面螺钉环的结果,并且与骨水泥髋臼杯以及非骨水泥、压配、金属背衬髋臼杯的结果相比具有优势。