Lehmann J F, Warren C G, Hertling D, McGee M, Simons B C, Dralle A
Arch Phys Med Rehabil. 1976 Sep;57(9):438-42.
The Craig-Scott double upright knee ankle orthosis was subjected to a biomechanical evaluation which included analysis of the force interaction with the supported limb and a functional evaluation. The results were compared with data previously determined from biomechanical evaluations of other common orthoses. In the Craig-Scott design, the single application of the knee stabilizing force below the knee concentrates this force in a relatively small bony area, sometimes exceeding tolerance. This might be avoided by using a tibial closure with patellar tendon bearing features. The design was found to produce relatively low anatomic knee shear. In functional aspects such as donning, doffing, transfers and ambulation, the orthosis is essentially equivalent to other double upright designs. The rigidity of the orthosis with only a tibial band closure and a bail connecting the uprights was determined to be adequate. The limited number of bands and closures provides some advantages in reduced donning and doffing time; however, in the absence of posterior closures below the knee, the orthosis had a tendency to slide forward off the leg when transferring. This disadvantage was eliminated by adding a soft posterior closure below the knee, which produced a minimal increase in donning and doffing times.
对克雷格 - 斯科特双直立式膝踝矫形器进行了生物力学评估,其中包括对与支撑肢体的力相互作用的分析以及功能评估。将结果与先前从其他常见矫形器的生物力学评估中确定的数据进行了比较。在克雷格 - 斯科特设计中,在膝盖下方单一施加膝盖稳定力会使该力集中在相对较小的骨区域,有时会超过耐受性。这可以通过使用具有髌腱承重特征的胫骨闭合装置来避免。发现该设计产生的解剖学膝盖剪切力相对较低。在诸如穿戴、脱卸、转移和行走等功能方面,该矫形器基本上与其他双直立设计相当。仅带有胫骨带闭合和连接立柱的吊环的矫形器的刚性被确定为足够。带子和闭合装置数量有限在减少穿戴和脱卸时间方面具有一些优势;然而,由于膝盖下方没有后部闭合装置,该矫形器在转移时倾向于从腿部向前滑落。通过在膝盖下方添加柔软的后部闭合装置消除了这一缺点,这在穿戴和脱卸时间上产生了最小的增加。