Bourne W M, Holtan S B, Hodge D O
Department of Ophthalmology, Mayo Clinic and Mayo Foundation, Rochester, Minnesota 55905, USA.
Cornea. 1999 Jan;18(1):29-33.
To record morphologic changes that occur in corneal endothelial cells during daily wear of rigid, gas-permeable fluorocarbon contact lenses during 3 years.
Nineteen new wearers and 32 previous wearers were fitted with daily-wear fluorocarbon contact lenses. Photographic images of the central corneal endothelium and central corneal thickness measurements were recorded at baseline, 2 months, and 1, 2, and 3 years after fitting.
In the new wearers, an increase in the coefficient of variation of cell area was present by 2 months after lens fitting and increased further over the subsequent 3 years. The increase in coefficient of variation of cell area was correlated with the oxygen transmissibility of the lens. Endothelial cell density was decreased at 2 and 3 years. Corneal thickness did not change. In the previous lens wearers after 3 years, there were no significant changes from baseline in any morphologic value. Corneal thickness was decreased significantly.
Although oxygen transmissibility in fluorocarbon contact lenses is improved over previous hard and soft lenses, polymegethism still was induced within 2 months by these lenses, and morphologic changes present from past lens wear did not improve during 3 years of daily wear.
记录在3年期间每日佩戴硬性透气氟碳接触镜时角膜内皮细胞发生的形态学变化。
19名新佩戴者和32名既往佩戴者佩戴每日佩戴型氟碳接触镜。在基线、配镜后2个月以及配镜后1年、2年和3年记录中央角膜内皮的摄影图像以及中央角膜厚度测量值。
在新佩戴者中,配镜后2个月时细胞面积变异系数增加,并在随后3年中进一步增加。细胞面积变异系数的增加与镜片的透氧性相关。2年和3年时内皮细胞密度降低。角膜厚度未改变。在既往佩戴镜片者中,3年后任何形态学值与基线相比均无显著变化。角膜厚度显著降低。
尽管氟碳接触镜的透氧性比以往的硬性和软性镜片有所改善,但这些镜片仍在2个月内诱发了细胞大小不均,并且既往佩戴镜片引起的形态学变化在3年的每日佩戴期间并未改善。