Mulcahy J J
Indiana University Medical Center, Indianapolis, USA.
J Urol. 1999 Jan;161(1):193-5.
Lateral extrusion of a penile prosthesis cylinder is an uncommon but distressing problem. A technique is described to reseat the cylinder in a more medial and secure position under the glans penis by creating a new cavity for the cylinder behind the back wall of the fibrotic sheath containing it.
A total of 14 patients underwent corporoplasty using this technique with followup as long as 2 years.
All patients had a satisfactory result with no recurrence of the original problem.
This method which places the cylinder behind 2 secure layers is straightforward, simple and reliable.
阴茎假体圆柱体的侧向挤压是一个罕见但令人苦恼的问题。本文描述了一种技术,通过在包含圆柱体的纤维化鞘后壁后方为圆柱体创建一个新腔,将圆柱体重新安置在阴茎头下方更内侧且更稳固的位置。
共有14例患者采用该技术进行了阴茎成形术,并进行了长达2年的随访。
所有患者均取得满意效果,原问题未复发。
这种将圆柱体置于两层稳固结构后方的方法直接、简单且可靠。