Hofherr L K, Peddecord K M, Benenson A S, Garfein R S, Francis D P, Ferran K L, Taylor R N
College of Health and Human Services, San Diego State University, CA 92182.
Clin Lab Sci. 1992 May-Jun;5(3):160-4.
The method developed for establishing a blind proficiency testing (PT) system is presented. The Laboratory Assurance Program of the Graduate School of Public Health at San Diego State University is developing and pilot testing innovative strategies that will evaluate and improve the performance of clinical laboratories. To date, a total of 32 laboratories have been incorporated into this program along with 12 counseling and testing sites. From June 1988 to December 1989, five blind PT surveys for human immunodeficiency virus type 1 antibody testing were conducted, representing 306 proficiency specimens entered into the testing system as simulated patient specimens. Despite the difficulties and expense involved, we found the system to be acceptable and to have certain advantages over conventional methods of external testing.
本文介绍了为建立盲法能力验证(PT)系统而开发的方法。圣地亚哥州立大学公共卫生研究生院的实验室保证计划正在开发和试点测试创新策略,以评估和提高临床实验室的性能。迄今为止,该计划已纳入32个实验室以及12个咨询和检测点。从1988年6月到1989年12月,进行了五次1型人类免疫缺陷病毒抗体检测的盲法PT调查,共有306份能力验证标本作为模拟患者标本进入检测系统。尽管存在困难和费用,但我们发现该系统是可以接受的,并且比传统的外部检测方法具有某些优势。