Stuber M, Fischer S E, Scheidegger M B, Boesiger P
Institute of Biomedical Engineering and Medical Informatics, University of Zurich and ETHZ, Switzerland.
Magn Reson Med. 1999 Mar;41(3):639-43. doi: 10.1002/(sici)1522-2594(199903)41:3<639::aid-mrm31>3.0.co;2-4.
Magnetic resonance imaging with preceding tissue tagging is a robust method for assessing cardiac motion of the entire heartbeat cycle with a high degree of accuracy. One limitation of this technique, however, is the low resolution of the obtained displacement map of the labeled points within the myocardium. By a new tagging technique, which is based on the combination of two or more measurements of the same slice but with different grid positions, a highly improved resolution of cardiac motion data can be achieved. In combination with a multi-heart-phase echo-planar imaging sequence, such images with doubled grid frequency can be acquired in two short breath-hold periods.
带有预先组织标记的磁共振成像,是一种用于高度精确评估整个心跳周期心脏运动的可靠方法。然而,该技术的一个局限性是,所获得的心肌内标记点位移图的分辨率较低。通过一种基于对同一层面进行两次或更多次测量但网格位置不同的新标记技术,可以实现心脏运动数据分辨率的大幅提高。结合多心脏相位回波平面成像序列,在两个短屏气期内即可采集到具有双倍网格频率的此类图像。