Suppr超能文献

基于欠采样投影重建的心肌壁标记

Myocardial wall tagging with undersampled projection reconstruction.

作者信息

Peters D C, Epstein F H, McVeigh E R

机构信息

Laboratory of Cardiac Energetics, National Institutes of Health, Bethesda, Maryland 20892-1061, USA.

出版信息

Magn Reson Med. 2001 Apr;45(4):562-7. doi: 10.1002/mrm.1076.

Abstract

Azimuthally undersampled projection reconstruction (PR) acquisition is investigated for use in myocardial wall tagging with MR using grid tags to provide increased temporal and spatial resolution. PR can provide the high-resolution images required for tagging with very few projections, at the expense of artifact. Insight is provided into the PR undersampling artifact, in the context of measuring myocardial motion with tags. For Fourier transform imaging, at least 112 phase-encodings must be collected to image tagging grids spaced 7 pixels apart. PR requires about 80 projections, a 1.4-fold reduction in scan time. Magn Reson Med 45:562-567, 2001. Published 2001 Wiley-Liss, Inc.

摘要

研究了方位欠采样投影重建(PR)采集技术在磁共振心肌壁标记中的应用,采用网格标记以提高时间和空间分辨率。PR能够以很少的投影次数提供标记所需的高分辨率图像,但代价是会产生伪影。在使用标记测量心肌运动的背景下,深入了解了PR欠采样伪影。对于傅里叶变换成像,必须采集至少112个相位编码才能对间距为7像素的标记网格进行成像。PR需要约80次投影,扫描时间减少了1.4倍。《磁共振医学》45:562 - 567,2001年。2001年由威利 - 利斯公司出版。

相似文献

1
Myocardial wall tagging with undersampled projection reconstruction.
Magn Reson Med. 2001 Apr;45(4):562-7. doi: 10.1002/mrm.1076.
2
Efficient radial tagging CMR exam: A coherent k-space reading and image reconstruction approach.
Magn Reson Med. 2017 Apr;77(4):1459-1472. doi: 10.1002/mrm.26219. Epub 2016 Mar 28.
3
Undersampled projection reconstruction applied to MR angiography.
Magn Reson Med. 2000 Jan;43(1):91-101. doi: 10.1002/(sici)1522-2594(200001)43:1<91::aid-mrm11>3.0.co;2-4.
4
A modified projection reconstruction trajectory for reduction of undersampling artifacts.
J Magn Reson Imaging. 2005 Feb;21(2):179-86. doi: 10.1002/jmri.20248.
5
6
Characterizing radial undersampling artifacts for cardiac applications.
Magn Reson Med. 2006 Feb;55(2):396-403. doi: 10.1002/mrm.20782.
8
Projection reconstruction balanced fast field echo for interactive real-time cardiac imaging.
Magn Reson Med. 2001 Dec;46(6):1238-41. doi: 10.1002/mrm.1322.
9
Reconstructing MR images from undersampled data: data-weighting considerations.
Magn Reson Med. 2000 Jun;43(6):867-75. doi: 10.1002/1522-2594(200006)43:6<867::aid-mrm13>3.0.co;2-2.

引用本文的文献

1
O-space with high resolution readouts outperforms radial imaging.
Magn Reson Imaging. 2017 Apr;37:107-115. doi: 10.1016/j.mri.2016.11.012. Epub 2016 Nov 20.
2
Quantification of regional myocardial wall motion by cardiovascular magnetic resonance.
Quant Imaging Med Surg. 2014 Oct;4(5):345-57. doi: 10.3978/j.issn.2223-4292.2014.09.01.
4
Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.
Magn Reson Med. 2014 Dec;72(6):1620-8. doi: 10.1002/mrm.25074. Epub 2014 Jan 17.
5
Cardiovascular magnetic resonance artefacts.
J Cardiovasc Magn Reson. 2013 May 22;15(1):41. doi: 10.1186/1532-429X-15-41.
6
Lifetime of combustion-generated environmentally persistent free radicals on Zn(II)O and other transition metal oxides.
J Environ Monit. 2012 Oct 26;14(10):2803-6. doi: 10.1039/c2em30545c. Epub 2012 Sep 18.
7
Undersampled cine 3D tagging for rapid assessment of cardiac motion.
J Cardiovasc Magn Reson. 2012 Aug 30;14(1):60. doi: 10.1186/1532-429X-14-60.
8
Formation and stabilization of combustion-generated, environmentally persistent radicals on Ni(II)O supported on a silica surface.
Environ Sci Technol. 2012 Sep 4;46(17):9406-11. doi: 10.1021/es301136d. Epub 2012 Aug 17.
10
Myocardial tagging with steady state free precession techniques and semi-automatic postprocessing--impact on diagnostic value.
Eur Radiol. 2007 Sep;17(9):2218-24. doi: 10.1007/s00330-007-0639-5. Epub 2007 Apr 19.

本文引用的文献

2
Optimization of tag thickness for measuring position with magnetic resonance imaging.
IEEE Trans Med Imaging. 1994;13(1):152-60. doi: 10.1109/42.276154.
3
Global alterations in mechanical function in healed reperfused first anterior myocardial infarction.
J Cardiovasc Magn Reson. 2000;2(1):33-41. doi: 10.3109/10976640009148671.
4
Single breath-hold 3D contrast-enhanced method for assessment of cardiac function.
Magn Reson Med. 2000 Dec;44(6):821-4. doi: 10.1002/1522-2594(200012)44:6<821::aid-mrm1>3.0.co;2-s.
5
Undersampled projection reconstruction applied to MR angiography.
Magn Reson Med. 2000 Jan;43(1):91-101. doi: 10.1002/(sici)1522-2594(200001)43:1<91::aid-mrm11>3.0.co;2-4.
6
SENSE: sensitivity encoding for fast MRI.
Magn Reson Med. 1999 Nov;42(5):952-62.
7
Unaliasing by fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI.
Magn Reson Med. 1999 Nov;42(5):813-28. doi: 10.1002/(sici)1522-2594(199911)42:5<813::aid-mrm1>3.0.co;2-s.
8
Signal-to-noise ratio and signal-to-noise efficiency in SMASH imaging.
Magn Reson Med. 1999 May;41(5):1009-22. doi: 10.1002/(sici)1522-2594(199905)41:5<1009::aid-mrm21>3.0.co;2-4.
9
Projection-reconstruction reduced [correction of reduces] FOV imaging.
Magn Reson Imaging. 1999 May;17(4):517-25. doi: 10.1016/s0730-725x(98)00212-4.
10
Toward high-resolution myocardial tagging.
Magn Reson Med. 1999 Mar;41(3):639-43. doi: 10.1002/(sici)1522-2594(199903)41:3<639::aid-mrm31>3.0.co;2-4.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验