Technetium-99m labeled peptides--an investigation of multiple HPLC peaks.

作者信息

Hnatowich D J, Chang F, Qu T, Rusckowski M

机构信息

Department of Nuclear Medicine, University of Massachusetts Medical Center, Worcester 01655, USA.

出版信息

Appl Radiat Isot. 1999 May;50(5):911-21. doi: 10.1016/s0969-8043(98)00157-2.

Abstract

This laboratory, and others, have reported multiple radioactive peaks in the size exclusion high performance liquid chromatographic (HPLC) analysis of 99mTc-labeled peptides. In the case of one 99mTc-MAG3-labeled peptide studied in this laboratory, human neutrophil elastase inhibitor, all five radioactive peaks were shown to be due to active peptide rather than radiocontaminants. By a variety of experiments, the nature of these peaks have now been examined. A high molecular weight UV peak could be generated by heating the MAG3 coupled, but not the native, peptide. Furthermore, this UV peak did not appear upon heating the peptide if the sulfur within the MAG3 chelator was replaced with oxygen. This peak may therefore be due to polymers resulting from intermolecular disulfide bond formation between sulfurs in the MAG3 chelate and the peptide. Several peaks with apparent lower molecular weights were absent on analysis with a different size exclusion column with superior resolution in their molecular weight range. More importantly, they were also absent on analysis by SDS polyacrylamide gel electrophoresis. These "low" molecular weight radioactive peaks may therefore be due to interactions between the 99mTc-MAG3 chelate and the peptide which produce multiple molecular configurations of identical molecular weight but differing in shape, charge, isomerism or lipophilicity such that they are resolved under the conditions of certain analyses. In support of this possibility, lengthening the linker between MAG3 and the peptide reduced the number of radioactive peaks, while encouraging the interaction by replacing MAG3 with the shorter MAG2 seemed to increase the number of radioactive peaks. Finally, that the three "low" molecular weight radioactive peaks reappeared when a single peak fraction was reanalyzed suggests that the species responsible are in rapid equilibrium. One conclusion from this investigation is that the appearance of a single peak by any HPLC analysis offers no assurance that multiple peaks would not appear on alternative HPLC analyses. Evidence that each species is due to radiolabeled active peptide and not to radiocontaminants is therefore potentially more important than evidence of a single peak.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验