Li R, Zhuravlev V L, Bychkow R E, Safonova T A
Department of Biology, Lanzhou University.
Zhongguo Ying Yong Sheng Li Xue Za Zhi. 1997 Nov;13(4):366-8.
An improved device of the adhesive electrode for recording the bioelectrical potential of animal's syncytial tissue is described in this paper. The main feature of the new device is to place a small chamber between the syringe for building negative pressue and the adhesive electrode. This chamber can keep the electric connection between amplifier and the tissue being recorded, and be placed near the tissue. The negative pressure can be conducted from the syringe by a plastic tube, so the syringe can be placed in any place where it doesn't affect the experiment. By using this new device, good results can be achieved when bioelectrical potential of hearts or gastric muscle of molluscan snails or frogs etc. is recorded. This simple and easy-operating device is practically valuable on studies of the normal functions and pharmacological effects in small animal's syncytial tissues such as heart, and gastric muscle.
本文描述了一种用于记录动物合胞体组织生物电电位的改进型粘贴电极装置。新装置的主要特点是在用于产生负压的注射器和粘贴电极之间设置一个小室。该小室能保持放大器与被记录组织之间的电连接,并可放置在靠近组织的位置。负压可通过塑料管从注射器传导过来,这样注射器可放置在不影响实验的任何位置。使用这种新装置,在记录软体动物蜗牛或青蛙等的心脏或胃肌生物电电位时能取得良好效果。这种简单易操作的装置在研究诸如心脏和胃肌等小动物合胞体组织的正常功能和药理作用方面具有实际价值。