Bergman B, Nilson H, Andersson M
Department of Prosthetic Dentistry, Faculty of Odontology, Umeå University, Sweden.
Int J Prosthodont. 1999 Mar-Apr;12(2):135-9.
The purpose of the present paper was to study the long-term clinical results with ceramic-veneered Procera titanium copings.
A total of 44 titanium copings (fabricated for 22 patients) veneered with a low-fusing ceramic were followed for 60 to 78 months. The clinical examinations were performed by licensed specialists in prosthetic dentistry. The crowns were rated according to the California Dental Association system. In addition, Bleeding Index and Margin Index were also evaluated.
In 3 crowns ceramic fractures necessitated their replacement. Two crowns had to be replaced because of caries. The ratings for surface and color had changed markedly, from excellent to acceptable. Regarding anatomic form, with the exception of the 3 fractured ceramic crowns, there were no obvious changes. The margin integrity, aside from the 2 crowned teeth with caries, was recorded as satisfactory (excellent or acceptable) for all other crowns; in fact, a large majority were rated excellent. Regarding Bleeding Index, there were no differences between crowned teeth and control teeth. Changes in Margin Index showed that the gingiva of the crowned teeth had retracted.
Of the various clinical factors evaluated, only surface and color-related to the low-fusing ceramic used for veneering-showed any obvious change during the follow-up period. Otherwise the veneered titanium copings had, in general, performed well.
本文旨在研究烤瓷熔附的Procera钛基底冠的长期临床效果。
对44个钛基底冠(为22例患者制作)进行了为期60至78个月的随访,这些基底冠均采用低熔烤瓷贴面。临床检查由有执照的口腔修复专科医生进行。根据加利福尼亚牙科协会系统对牙冠进行评级。此外,还评估了出血指数和边缘指数。
3个牙冠因陶瓷碎裂需要更换。2个牙冠因龋齿需要更换。表面和颜色评级从优秀显著变为可接受。关于解剖形态,除3个陶瓷碎裂的牙冠外,无明显变化。除2个患龋的带冠牙外,所有其他牙冠的边缘完整性记录为满意(优秀或可接受);事实上,绝大多数被评为优秀。关于出血指数,带冠牙与对照牙之间无差异。边缘指数的变化表明带冠牙的牙龈退缩。
在评估的各种临床因素中,随访期间只有与用于贴面的低熔陶瓷相关的表面和颜色出现了明显变化。否则,烤瓷熔附钛基底冠总体表现良好。