Suppr超能文献

用于在患者家中监测哮喘严重程度的远程信息处理系统。

Telematic system for monitoring of asthma severity in patients' homes.

作者信息

Finkelstein J, Hripcsak G, Cabrera M

机构信息

Department of Medical Informatics, Columbia University, New York, USA.

出版信息

Stud Health Technol Inform. 1998;52 Pt 1:272-6.

Abstract

Despite advances in the treatment of asthma the morbidity and mortality of this disease has increased significantly in the past several years. Recent studies have shown that monitoring of asthma severity in the patient home especially combined with patient education can reduce incidence of asthma exacerbation and subsequent hospitalization. The existing methods for home asthma monitoring are limited by four factors; they completely rely on a patient's ability to document and to evaluate test results; there is no easy way for a physician to review data in a timely manner; they use imprecise tools for evaluation of asthma severity and they don't provide clinical decision support tools. The goal of this study is to develop and to evaluate a telematic system for asthma severity monitoring which will minimize patients' efforts in performing self-testing at their homes and allow prompt reciprocal exchange of all relevant information between patients and health care providers. In our setting, patients use portable spirometer and pocket-sized palmtop computer for data exchange. Our system allows daily serial monitoring of asthma severity at patients' homes using Forced Vital Capacity test and symptom diary. The results of the tests become available for physicians review immediately after completion of self-testing procedures via Web browser. The results can be transmitted from patients' homes (or any other remote location) to the medical records database via landline or wireless networks in several minutes. Each time the remote server receives patient's results, it invokes the application which tests the validity of data, analyzes parameters trends and dispatches corresponding messages for the patient and, if necessary, for physicians. Such an approach provides constant feedback loop between asthma patient and physician. The system has been tested in 10 healthy volunteers and asthma patients. Patients participated in the study from two to 21 days. The test results showed that the system provides reliable reciprocal exchange of all relevant information between a physician and asthma patient in home settings. Average transmission time from the patient's palmtop to the remote central data repository was about 1 minute for 14.4 Kbps landline modem, 6 minutes for cellular network and 8 minutes for RAM Mobile network. After transmission, the test results were immediately available for review at our web site.

摘要

尽管在哮喘治疗方面取得了进展,但在过去几年中,这种疾病的发病率和死亡率仍显著上升。最近的研究表明,在患者家中监测哮喘严重程度,特别是结合患者教育,可以降低哮喘发作的发生率以及随后的住院率。现有的家庭哮喘监测方法受到四个因素的限制:它们完全依赖患者记录和评估测试结果的能力;医生没有简便的方法及时查看数据;它们使用不精确的工具来评估哮喘严重程度,并且不提供临床决策支持工具。本研究的目的是开发并评估一种用于哮喘严重程度监测的远程信息系统,该系统将最大限度地减少患者在家中进行自我测试的工作量,并允许患者与医疗保健提供者之间迅速相互交换所有相关信息。在我们的研究中,患者使用便携式肺活量计和袖珍掌上电脑进行数据交换。我们的系统允许使用用力肺活量测试和症状日记在患者家中每日连续监测哮喘严重程度。自测程序完成后,测试结果可立即通过网络浏览器供医生查看。测试结果可在几分钟内通过固定电话或无线网络从患者家中(或任何其他远程位置)传输到医疗记录数据库。每次远程服务器接收到患者的结果时,它会调用应用程序来测试数据的有效性,分析参数趋势,并为患者(必要时也为医生)发送相应的消息。这种方法在哮喘患者和医生之间提供了持续的反馈循环。该系统已在10名健康志愿者和哮喘患者中进行了测试。患者参与研究的时间为2至21天。测试结果表明,该系统在家庭环境中为医生和哮喘患者之间提供了可靠的所有相关信息的相互交换。对于14.4 Kbps的固定电话调制解调器,从患者掌上电脑到远程中央数据存储库的平均传输时间约为1分钟,蜂窝网络为6分钟,RAM移动网络为8分钟。传输后,测试结果可立即在我们的网站上供查看。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验