Suppr超能文献

一种用于血浆样品快速直接进样分析的多功能高流量高效液相色谱-串联质谱系统,用于定量一种β-内酰胺类候选药物及其开环生物转化产物。

A versatile system of high-flow high performance liquid chromatography with tandem mass spectrometry for rapid direct-injection analysis of plasma samples for quantitation of a beta-lactam drug candidate and its open-ring biotransformation product.

作者信息

Jemal M, Ouyang Z, Xia Y Q, Powell M L

机构信息

Bristol-Myers Squibb Pharmaceutical Research Institute, Bioanalytical Research, Metabolism and Pharmacokinetics, P.O. Box 191, New Brunswick, NJ 08903-0191, USA.

出版信息

Rapid Commun Mass Spectrom. 1999;13(14):1462-71. doi: 10.1002/(SICI)1097-0231(19990730)13:14<1462::AID-RCM668>3.0.CO;2-Z.

Abstract

A bioanalytical method has been developed and validated for quantitation of a beta-lactam drug candidate and its open-ring biotransformation product utilizing high-flow high-performance liquid chromatography (HPLC) for on-line purification of plasma samples and electrospray tandem mass spectrometry for detection and quantitation. The HPLC system used two columns: an Oasis column (1 x 50 mm, 30 microm) as the on-line extraction column and a conventional C18 column (2 x 50 mm, 5 microm) as the analytical column. Each plasma standard or quality control (QC) sample (50 microL) was mixed with 50 microL of a working solution of the internal standard in aqueous 0.5 M ammonium acetate (pH 4.0). Portions (10 microL) of these samples were then injected into an Oasis column with a mobile phase consisting of 100% aqueous 1 mM formic acid at a high flow rate (4.0 mL/min), with the effluent from the Oasis column directed to waste and not to the mass spectrometer. After the purification step, the Oasis column effluent was directed to the analytical column and the mass spectrometer and the analytes were eluted with methanol/aqueous 1 mM formic acid (70:30) at a flow rate of 1.0 mL/min. The total analysis time was 1.6 min per sample. The standard curve range was 0.980 to 250 ng/mL. The accuracy, inter-day precision and intra-day precision were within 10% for both compounds.

摘要

已开发并验证了一种生物分析方法,用于定量一种β-内酰胺候选药物及其开环生物转化产物,该方法利用高流量高效液相色谱(HPLC)在线净化血浆样品,并采用电喷雾串联质谱进行检测和定量。HPLC系统使用两根色谱柱:一根Oasis柱(1×50mm,30μm)作为在线萃取柱,一根常规C18柱(2×50mm,5μm)作为分析柱。将每个血浆标准品或质量控制(QC)样品(50μL)与50μL内标工作溶液在0.5M醋酸铵水溶液(pH4.0)中混合。然后将这些样品的部分(10μL)注入Oasis柱,流动相为100%含1mM甲酸的水溶液,流速为4.0mL/min,Oasis柱的流出物直接排至废液,不接入质谱仪。在净化步骤之后,将Oasis柱的流出物导向分析柱和质谱仪,用甲醇/含1mM甲酸的水溶液(70:30)以1.0mL/min的流速洗脱分析物。每个样品的总分析时间为1.6分钟。标准曲线范围为0.980至250ng/mL。两种化合物的准确度、日间精密度和日内精密度均在10%以内。

相似文献

3
Ternary-column system for high-throughput direct-injection bioanalysis by liquid chromatography/tandem mass spectrometry.
Rapid Commun Mass Spectrom. 2000;14(2):105-11. doi: 10.1002/(SICI)1097-0231(20000130)14:2<105::AID-RCM842>3.0.CO;2-Q.
4
Direct injection versus liquid-liquid extraction for plasma sample analysis by high performance liquid chromatography with tandem mass spectrometry.
Rapid Commun Mass Spectrom. 1999;13(21):2125-32. doi: 10.1002/(SICI)1097-0231(19991115)13:21<2125::AID-RCM763>3.0.CO;2-H.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验