A diagnostic test study was conducted to evaluate the diagnostic performance of a simple urinalysis as a screening test for asymptomatic bacteriuria (ABU) in pregnant women. Seven hundred and seventy four asymptomatic pregnant women attending their first antenatal care at Srinagarind Hospital from June 1, 1994 to January 31, 1995 were studied. Simple urinalysis and urine culture were performed on all 774 subjects. The presence of > or = 5 WBC/HPF of centrifuged urine indicated a positive test. ABU was defined as the presence of > or = 10(5) colony forming units of single bacteria per milliliter of urine. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of simple urinalysis in detecting ABU, using urine culture as a gold standard were calculated. Simple urinalysis had a 18.4 per cent sensitivity, 97.2 per cent specificity, 45.7 per cent positive predictive value, 90.4 per cent negative predictive value and 88.4 per cent accuracy in detecting ABU. Because of its low sensitivity and the possible consequences of ABU, simple urinalysis should not be used as a screening test for ABU.
开展了一项诊断试验研究,以评估简单尿液分析作为孕妇无症状菌尿(ABU)筛查试验的诊断性能。对1994年6月1日至1995年1月31日在诗里拉吉医院进行首次产前检查的774名无症状孕妇进行了研究。对所有774名受试者进行了简单尿液分析和尿培养。离心尿中白细胞≥5个/高倍视野表明试验阳性。ABU定义为每毫升尿液中单一细菌的菌落形成单位≥10⁵。以尿培养作为金标准,计算了简单尿液分析检测ABU的敏感性、特异性、阳性预测值、阴性预测值和准确性。简单尿液分析检测ABU的敏感性为18.4%,特异性为97.2%,阳性预测值为45.7%,阴性预测值为90.4%,准确性为88.4%。由于其低敏感性以及ABU可能产生的后果,简单尿液分析不应作为ABU的筛查试验。