Suppr超能文献

通过石英晶体微量天平与安德森级联撞击器测定的定量吸入器的空气动力学粒径。

Aerodynamic particle size of metered-dose inhalers determined by the quartz crystal microbalance and the Andersen cascade impactor.

作者信息

Tzou T Z

机构信息

Inhalation Drug Delivery Laboratory, Building 260-4N-12, 3M Pharmaceuticals, St. Paul, MN 55144, USA.

出版信息

Int J Pharm. 1999 Sep 10;186(1):71-9. doi: 10.1016/s0378-5173(99)00139-8.

Abstract

Given the rapid sizing capability and high sensitivity, the quartz crystal microbalance (QCM) cascade impactor has been evaluated for the size determination of metered-dose inhaler (MDI) aerosols. The effects of surfactants present in MDI formulations, crystal coating, particle bounce and crystal overloading on the QCM cascade impactor are investigated. To reduce particle bounce, it is necessary to coat the crystals and use new coated surfaces for each measurement. Mass median aerodynamic diameters (MMADs) obtained from the QCM cascade impactor are compared to those from the commonly used Andersen cascade impactor. For MDI formulations containing little or no surfactants, MMADs obtained from the QCM and Andersen cascade impactors are comparable. For MDI formulations containing a significant amount of surfactant (or any non-volatile excipients), the QCM cascade impactor measures the combined size distribution of the drug and non-volatile excipients. A technique is devised in this study to deduce the drug-only size distribution from the QCM impactor for surfactant-containing MDI formulations and show comparable results to the Andersen cascade impactor except for high drug load Intal. The QCM impactor has proved to be a useful tool for rapid size measurement of MDI formulations.

摘要

鉴于石英晶体微天平(QCM)级联撞击器具有快速筛分能力和高灵敏度,已对其用于定量吸入器(MDI)气雾剂粒径测定进行了评估。研究了MDI制剂中存在的表面活性剂、晶体涂层、颗粒反弹和晶体过载对QCM级联撞击器的影响。为减少颗粒反弹,有必要对晶体进行涂层处理,并在每次测量时使用新的涂层表面。将从QCM级联撞击器获得的质量中值空气动力学直径(MMAD)与常用的安德森级联撞击器获得的结果进行比较。对于含有很少或不含表面活性剂的MDI制剂,从QCM和安德森级联撞击器获得的MMAD具有可比性。对于含有大量表面活性剂(或任何非挥发性辅料)的MDI制剂,QCM级联撞击器测量的是药物和非挥发性辅料的综合粒径分布。本研究设计了一种技术,用于从QCM撞击器推导含表面活性剂的MDI制剂中仅药物的粒径分布,并显示出与安德森级联撞击器可比的结果,但高药物负荷的因他米松(Intal)除外。QCM撞击器已被证明是一种用于快速测量MDI制剂粒径的有用工具。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验