Comparative analysis of quantification of viral load in patients infected with hepatitis C virus: quantiplex HCV RNA assay and amplicor monitor assay.

作者信息

Olaso V, Córdoba J, López B, Argüello L, Molina J, Lainez B, Ortiz V, Pastor M, Prieto M, Berenguer J

机构信息

Servicio de Medicina Digestiva, Hospital "La Fe", Valencia, 46009, España.

出版信息

Rev Esp Enferm Dig. 1999 Aug;91(8):569-82.

Abstract

OBJECTIVE

two standardized techniques, Quantiplex HCV RNA 2.0 (bDNA) and Amplicor Monitor, were evaluated for the quantification of hepatitis C virus (HCV) load. Our objectives were: 1) to determine the relationship between viral load and genotype, and 2) to evaluate viral load in serial serum samples and in patients with normal or slightly elevated liver enzyme values in an area with a high prevalence of genotype 1.

RESULTS

the viral loads detected with the two methods correlated significantly (r = 0.7, p < 0.0001), but viral load was smaller with the Monitor than with the Quantiplex assay, and was independent of genotype. The Monitor/Quantiplex ratio was lower in patients with a non-1 genotype than in patients with genotype 1b. Virological characteristics were similar in patients with normal or slightly elevated enzyme levels and in patients with elevated enzyme values. Neither method showed a relationship between viral load and age, sex, duration of the infection, mode of transmission, or histological activity index.

CONCLUSION

viral load was not dependent on genotype. Measurement of viral load in a single serum sample adequately reflected the viral load measured in several serum samples from patients with chronic HCV infection. Patients with normal liver enzyme levels are not good candidates, in virological terms, for treatment with interferon.