Guidewire manipulation through tortuosities is difficult. Straightening a tortuous coronary artery by using a stiff guidewire has been recognized to induce vessel wall shortening referred to as an "accordion phenomenon." With inappropriate identification as dissection or thrombus formation, the risk of performing unnecessary dilation at the pseudo-narrowing site exists. The authors describe here two cases showing the accordion phenomenon induced by a stiff guidewire during successful stenting at a tortuous right coronary artery. In another case, the authors experienced an "accordion phenomenon" at the proximal edge of the Palmaz-Schatz stent implanted in a tortuous right coronary artery. The stent edge was better positioned at the straight portion than at the contour portion in a tortuous coronary artery.
将导丝操控通过迂曲血管很困难。使用硬导丝拉直迂曲的冠状动脉已被认为会导致血管壁缩短,即所谓的“手风琴现象”。若错误地认定为夹层或血栓形成,就存在在假性狭窄部位进行不必要扩张的风险。作者在此描述两例在成功对迂曲的右冠状动脉进行支架置入过程中由硬导丝诱发手风琴现象的病例。在另一例中,作者在植入于迂曲右冠状动脉的帕尔马茨-沙茨支架近端边缘经历了“手风琴现象”。在迂曲冠状动脉中,支架边缘在直线部分比在轮廓部分定位更好。