Gould K G, Warner H, Martin D E
J Med Primatol. 1978;7(4):213-22. doi: 10.1159/000459881.
The technique of rectal probe electroejaculation has been developed to permit collection of semen using equipment proven safe, simple, and effective on the 30 primate species so far tested. This paper provides information on the construction and operation of this equipment, together with electrical parameters applicable to primate species. Seminal emission or ejaculation occurs in all species when alternating current is delivered at 0.25 mA/mm2 electrode area. The most effective frequency is 20 Hz, and the most acceptable anesthetic is ketamine hydrochloride.
直肠探头电射精技术已被开发出来,以便使用已在迄今测试的30种灵长类动物身上证明安全、简单且有效的设备来采集精液。本文提供了有关该设备的构造和操作的信息,以及适用于灵长类动物的电参数。当以0.25 mA/mm²电极面积输送交流电时,所有物种都会出现射精或遗精。最有效的频率是20赫兹,最可接受的麻醉剂是盐酸氯胺酮。